A metal-ceramic coaxial cable Fabry-Pérot microwave interferometer for monitoring fluid dielectric constant

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Metal-Ceramic Coaxial Cable Fabry-Pérot Interferometric Sensors for High Temperature Monitoring

Metal-ceramic coaxial cable Fabry-Pérot interferometric (MCCC-FPI) sensors have been developed using a stainless steel tube and a stainless steel wire as the outer and inner conductors, respectively; a tubular α-alumina insulator; and a pair of air gaps created in the insulator along the cable to serve as weak reflectors for the transmitting microwave (MW) signal. The MCCC-FPI sensors have been...

متن کامل

A Coaxial Cable Fabry-Perot Interferometer for Sensing Applications

This paper reports a novel coaxial cable Fabry-Perot interferometer for sensing applications. The sensor is fabricated by drilling two holes half-way into a coaxial cable. The device physics was described. The temperature and strain responses of the sensor were tested. The measurement error was calculated and analyzed.

متن کامل

Micromachined Fabry-Pérot interferometer with embedded nanochannels for nanoscale fluid dynamics.

We describe a microfabricated Fabry-Pérot interferometer with nanochannels of various heights between 6 and 20 nm embedded in its cavity. By multiple beam interferometry, the device enables the study of liquid behavior in the nanochannels without using fluorescent substances. During filling studies of ethanol and water, an intriguing filling mode for partially wetting water was observed, tentat...

متن کامل

Plasmonic Fabry-Pérot nanocavity.

We experimentally demonstrate a novel, all-plasmonic nanoscopic cavity exhibiting Q-factors up to 200 at visible frequencies. The Fabry-Pérot type resonator uses tall metallic fins that reflect up to 98% of incident surface plasmon to concentrate light within a subwavelength cavity mode. High aspect ratio metal fins, constructed using lithography and electroplating, reduce surface plasmon scatt...

متن کامل

Tunable Fabry-Pérot interferometer based on nanoporous anodic alumina for optical biosensing purposes

Here, we present a systematic study about the effect of the pore length and its diameter on the specular reflection in nanoporous anodic alumina. As we demonstrate, the specular reflection can be controlled at will by structural tuning (i.e., by designing the pore geometry). This makes it possible to produce a wide range of Fabry-Pérot interferometers based on nanoporous anodic alumina, which a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors and Actuators A: Physical

سال: 2017

ISSN: 0924-4247

DOI: 10.1016/j.sna.2017.02.004