A Mechanical Sensor Designed for Dynamic Joint Angle Measurement
نویسندگان
چکیده
منابع مشابه
A Mechanical Sensor Designed for Dynamic Joint Angle Measurement
Background. The measurement of the functional range of motion (FROM) of lower limb joints is an essential parameter for gait analysis especially in evaluating rehabilitation programs. Aim. To develop a simple, reliable, and affordable mechanical goniometer (MGR) for gait analysis, with six-degree freedom to dynamically assess lower limb joint angles. Design. Randomized control trials, in which ...
متن کاملA Multifunctional Joint Angle Sensor with Measurement Adaptability
The paper presents a multifunctional joint sensor with measurement adaptability for biological engineering applications, such as gait analysis, gesture recognition, etc. The adaptability is embodied in both static and dynamic environment measurements, both of body pose and in motion capture. Its multifunctional capabilities lay in its ability of simultaneous measurement of multiple degrees of f...
متن کاملCapacitive sensor for relative angle measurement
Based on a capacitive angle and angular rate sensor, a sensor measuring the relative angle between two rotating shafts has been developed. Two rotatable electrodes are placed between two sensor plates. The relative angle between the two rotors and the absolute position of the rotor blades are calculated from measurements of the capacitive coupling between different transmitting stator segments ...
متن کاملIMU-based Joint Angle Measurement Made Practical
This contribution is concerned with hinge joint angle calculation based on inertial measurement data in the context of human motion analysis. Unlike most robotic devices, the human body lacks even surfaces and right angles. Therefore, we focus on methods that avoid to assume a certain mounting orientation, i.e. certain orientations in which the sensor should be mounted with respect to the body ...
متن کاملIMU-Based Joint Angle Measurement for Gait Analysis
This contribution is concerned with joint angle calculation based on inertial measurement data in the context of human motion analysis. Unlike most robotic devices, the human body lacks even surfaces and right angles. Therefore, we focus on methods that avoid assuming certain orientations in which the sensors are mounted with respect to the body segments. After a review of available methods tha...