A mathematical and dosimetric approach to validate auto‐contouring by Varian Smart segmentation for prostate cancer patients
نویسندگان
چکیده
Purpose The aim of this study was to quantify the discrepancies in geometrical and dosimetric impacts (in volumetric modulated arc therapy) between manually segmented (MS) contours smart segmentation (SS) auto-contours (by Varian Eclipse Treatment Planning System SS v13.5) for prostate cancer patients. Methods automated carried out by (Varian, version 13.5) Smart Segmentation workspace 10 patients four regions interest; such as, bladder, rectum, femoral head left, right. geometric deviation MS have been quantified form different parameters. organ-wise correlation validation parameters addressed. Results analysis showed good consistent bladder. hypothesis test checking compliance with AAPM 132 tolerance addressed validated bladder p-value = 0.01 0.05. There no significant difference dose–volume histogram (DVH) estimated standard DVH constraints protocol (as per TMH PRIME trial) also not significant, Conclusion This shows that “well correlated infer correctly about matching or coincidence auto contours,” contouring plan optimization can achieve acceptable constraints.
منابع مشابه
a benchmarking approach to optimal asset allocation for insurers and pension funds
uncertainty in the financial market will be driven by underlying brownian motions, while the assets are assumed to be general stochastic processes adapted to the filtration of the brownian motions. the goal of this study is to calculate the accumulated wealth in order to optimize the expected terminal value using a suitable utility function. this thesis introduced the lim-wong’s benchmark fun...
15 صفحه اولa new approach to credibility premium for zero-inflated poisson models for panel data
هدف اصلی از این تحقیق به دست آوردن و مقایسه حق بیمه باورمندی در مدل های شمارشی گزارش نشده برای داده های طولی می باشد. در این تحقیق حق بیمه های پبش گویی بر اساس توابع ضرر مربع خطا و نمایی محاسبه شده و با هم مقایسه می شود. تمایل به گرفتن پاداش و جایزه یکی از دلایل مهم برای گزارش ندادن تصادفات می باشد و افراد برای استفاده از تخفیف اغلب از گزارش تصادفات با هزینه پائین خودداری می کنند، در این تحقیق ...
15 صفحه اول3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملDosimetric Comparison of Various Radiotherapeutic Treatment Plans Using Cobalt-60 and Linac for Prostate Cancer
Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...
متن کاملRadiation treatment planning for prostate cancer: A new dosimetric comparison of five and seven fields IMRT plans
Background: To compare the dosimetric coverage of the planning target volume (PTV) and the dose delivered to the main Organs at Risk (OARs) in 5 and 7-field techniques of Intensity Modulated Radiation Therapy (IMRT) in patients with local prostate cancer. Materials and Methods: Twelve patients with local prostate cancer underwent 5 and 7-field IMRT planning. The delivery of IMRT was carried out...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Precision radiation oncology
سال: 2022
ISSN: ['2398-7324']
DOI: https://doi.org/10.1002/pro6.1147