A MANUAL FOR DOSIMETRY OF HIGH ENERGY ELECTRON BEAMS IN RADIOTHERAPY
نویسندگان
چکیده
منابع مشابه
AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams.
A protocol is prescribed for clinical reference dosimetry of external beam radiation therapy using photon beams with nominal energies between 60Co and 50 MV and electron beams with nominal energies between 4 and 50 MeV. The protocol was written by Task Group 51 (TG-51) of the Radiation Therapy Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved ...
متن کاملIn Vivo Dosimetry Using a Flat Surface Sun Nuclear Corporation Diode in 60co Beams for Some Radiotherapy Treatments in Ghana
Introduction: One of the useful standard quality assurance techniques in radiation therapy is monitoring entrance doses in in-vivo dosimetry. An overall tolerance limit of 5% of the absorbed radiation dose has been recommended by the International Commission of Radiological Units. The implementation of an in vivo dosimet...
متن کاملA M Ller Polarimeter for High Energy Electron Beams
A single arm M ller polarimeter used to measure the longitudinal beam polarization of the 48 GeV electron beam for SLAC xed target experiment E{154 is described. The polarimeter utilizes an array of silicon strip detectors and a dipole magnetic spectrometer to detect M ller scattered electrons from magnetized Fe-Co alloy target foils. The details of the foil polarization measurements and analys...
متن کاملA Toroidal Charge Monitor for High - Energy Picosecond Electron Beams ?
A monitor system suitable for the accurate measurement of the total charge of a 2-ps 28.5 GeV electron beam over a large dynamic range is described. Systematic uncertainties and results on absolute calibration, resolution, and long-term stability are presented.
متن کاملA Mdler polarimeter for high energy electron beams
A single arm Msller polarimeter used to measure the longitudinal beam polarization of the 48GeV electron beam for SLAC fixed target experiment E-154 is described. The polarimeter utilizes an array of silicon strip detectors and a dipole magnetic spectrometer to detect Msller scattered electrons from magnetized Fe-Co alloy target foils. The details of the foil pol~ization measu~ments and analysi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1991
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00003532783