A Lumped-Parameter Subject-Specific Model of Blood Volume Response to Fluid Infusion
نویسندگان
چکیده
منابع مشابه
A Lumped-Parameter Subject-Specific Model of Blood Volume Response to Fluid Infusion
This paper presents a lumped-parameter model that can reproduce blood volume response to fluid infusion. The model represents the fluid shift between the intravascular and interstitial compartments as the output of a hypothetical feedback controller that regulates the ratio between the volume changes in the intravascular and interstitial fluid at a target value (called "target volume ratio"). T...
متن کاملA lumped parameter model of cerebral blood flow control combining cerebral autoregulation and neurovascular coupling.
Cerebral blood flow regulation is based on a variety of different mechanisms, of which the relative regulatory role remains largely unknown. The cerebral regulatory system expresses two regulatory properties: cerebral autoregulation and neurovascular coupling. Since partly the same mechanisms play a role in cerebral autoregulation and neurovascular coupling, this study aimed to develop a physio...
متن کاملDynamics of cerebral blood flow regulation explained using a lumped parameter model.
The dynamic cerebral blood flow response to sudden hypotension during posture change is poorly understood. To better understand the cardiovascular response to hypotension, we used a windkessel model with two resistors and a capacitor to reproduce beat-to-beat changes in middle cerebral artery blood flow velocity (transcranial Doppler measurements) in response to arterial pressure changes measur...
متن کاملWatgis: a Gis–based Lumped Parameter Water Quality Model
A Geographic Information System (GIS)–based, lumped parameter water quality model was developed to estimate the spatial and temporal nitrogen–loading patterns for lower coastal plain watersheds in eastern North Carolina. The model uses a spatially distributed delivery ratio (DR) parameter to account for nitrogen retention or loss along a drainage network. Delivery ratios are calculated from tim...
متن کاملParameter sensitivity analysis of a lumped-parameter model of a chain of lymphangions in series.
Any disruption of the lymphatic system due to trauma or injury can lead to edema. There is no effective cure for lymphedema, partly because predictive knowledge of lymphatic system reactions to interventions is lacking. A well-developed model of the system could greatly improve our understanding of its function. Lymphangions, defined as the vessel segment between two valves, are the individual ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Frontiers in Physiology
سال: 2016
ISSN: 1664-042X
DOI: 10.3389/fphys.2016.00390