A logarithmic, large-solid-angle detector telescope for nuclear fragmentation
نویسندگان
چکیده
منابع مشابه
A SILICON PHOTODIODE ARRAY DETECTOR COVERING A LARGE SOLID ANGLE FOR FLUORESCENCE EXAFS MEASUREMENTS FROM 2 TO 25 keV
A Si-photodiode array detector operated in the photovoltaic mode is shown to offer several advantages over other fluorescence detectors: high efficiency, perfect linearity of the response, vacuum compatibility for soft X-ray measurements, absence of gas and voltage supplies. Low temperature cooling down to 120°c is needed in order to decrease the dark current and thermal noise of the shunt resi...
متن کاملUsing Accurate Solid Angle Tools when Comparing EDS Detector Geometries
Analysts should strive for the EDS system that provides the highest efficiency for their analytical work. For detectors, that typically means starting with the geometry with the best solid angle (SA) value. Manufacturers should be designing interfaces to maximize the solid angle of the detectors without compromising the integrity of the electron columns. Accurate modeling of the solid angle is ...
متن کاملLarge zenith - angle observations with the CAT Cherenkov imaging telescope
We present here results from large zenith-angle observations with the CAT atmospheric Cherenkov imaging telescope, based on data taken on the Crab Nebula and on the blazar Mk501 from 1996 onwards. From Monte Carlo simulations, the threshold energy of the telescope is expected to vary from about 250 GeV at zenith to about 2 TeV at a zenith angle of 60 •. The lower source-fluxes due to the increa...
متن کاملA modular solid state detector for measuring high energy heavy ion fragmentation near the beam axis.
A multi-element solid state detector has been designed to measure fluences of fragments produced near the beam axis by high energy heavy ion beams in thick targets. The detector is compact and modular, so as to be readily reconfigured according to the range of fragment charges and energies to be measured. Preamplifier gain settings and detector calibrations are adjustable remotely under compute...
متن کاملA new multi-detector telescope calibration method
A new calibration method, applicable to multidetector telescopes, is presented. This method is based on the comparison between experimental data and the ones obtained from Monte-Carlo simulation. The method just needs a accurate knowledgment of the detector spectrum. To test the method, data obtained in GANIL accelerator, are used. Obtained results are presented and the method accuracy is concl...