A Linear Dose-Response Curve at the Motor Endplate
نویسندگان
چکیده
منابع مشابه
A Linear Dose-Response Curve at the Motor Endplate
The motor endplate of frog sartorius muscle was voltage clamped and the peak current to different concentrations of acetylcholine and carbachol applied in the perfusing fluid was measured. Perfusing fluid was hypertonic in order to suppress contractions. Current responses were smooth and reached a peak value within 2-5 s. The dose-response curve was usually linear even with concentrations of 10...
متن کاملLinear and Non - linear modeling of a dose - response curve using SAS
In clinical trials response variables are measured at different times and doses. This paper explores methods to determine the dose that optimizes the response based on multiple responses and doses. Linear dose-response modeling can be performed using repeated measures analysis (using PROC MIXED) for change in response (Y) using dose (X) as a continuous explanatory variable with time, dose, and ...
متن کاملDose-response curve of associative plasticity in human motor cortex and interactions with motor practice.
Associative plasticity is hypothesized to be an important neurophysiological correlate of memory formation and learning with potentials for applications in neurorehabilitation and for the development of new electrophysiological measures to study disorders of cortical plasticity. We hypothesized that the magnitude of the paired associative stimulation (PAS)-induced long-term potentiation (LTP)-l...
متن کاملDose response curve of Associative Plasticity in human motor 1 cortex and interactions with motor practice
24 Associative plasticity is hypothesized to be an important neurophysiological correlate of 25 memory formation and learning with potentials for applications in neurorehabilitation and for 26 the development as new electrophysiological measures to study disorders of cortical plasticity. 27 We hypothesized that magnitude of paired associative stimulation (PAS) induced long term 28 potentiation ...
متن کاملConstruction of a dose – response curve by induction of premature chromosome condensation for biological dosimetry
Premature Chromosome Condensation (PCC) appears to have a possible utility for biological dosimetry purposes. The PCC technique may be adapted for cases of suspicion of overexposure where sampling is performed at least one day after an accident. For this purpose, human blood samples were exposed in vitro to 60Co up to 10 Gy and the PCC technique was performed immediately after irradiation. Anal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of General Physiology
سال: 1973
ISSN: 1540-7748,0022-1295
DOI: 10.1085/jgp.62.1.58