A light readout system for gas TPCs

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Demonstration of Light Guides for Light Detection in Liquid Argon TPCs

Liquid Argon (LAr) Time Projection Chambers (TPCs) are a developing technology that is becoming a popular choice for neutrino and dark matter experiments due to the low cost of the LAr as a target material and the high signal efficiency and background rejection that these detectors can achieve. When excited by a passing charged particle created in a neutrino interaction, argon produces scintill...

متن کامل

A TPC with Triple-GEM Gas Amplification and TimePix Readout

We present measurements with a GEM based TPC prototypes and the TimePix CMOS ASIC as charge collecting anode. Tests with a small prototype were performed in a 5GeV electron beam at DESY. It is shown that the point resolution for short drift distances is better than 20 μm. The achieved time resolution is better than 10 ns at 100MHz clock frequency. Furthermore, experimental studies with an enlar...

متن کامل

CMOS Readout System for a Double-sided Germanium Strip Detector

A wide variety of applications require a hard Xray or gamma ray detector which combine both good spatial resolution and energy resolution. Double-sided solid-state strip detectors provide this capability. We report on the development of CMOS electronics designed for photon detection with strip detectors. These electronics include a low noise preamplifier, semi-gaussian shaping amplifier, discri...

متن کامل

Establishment of a positive-readout reporter system for siRNAs

The use of small interfering RNA molecules for therapeutic applications requires development of improved delivery systems, a process that would be facilitated by a non-invasive positive-readout mouse model for studying siRNA pharmacodynamics. Positive readout would yield better signal/noise ratios than existing negative-readout systems. We have engineered a positive-readout luciferase reporter ...

متن کامل

Toward Application of a Thick Gas Electron Multiplier (THGEM) Readout for a Dark Matter Detector

The Yale-Weizmann collaboration aims to develop a lowradioactivity (low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in measurements to be performed deep underground as for example carried out by the XENON collaboration. A major issue is the background induced by natural radioactivity of present-detector components including the Photo Multiplier Tubes (PMT) made from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Instrumentation

سال: 2014

ISSN: 1748-0221

DOI: 10.1088/1748-0221/9/01/p01005