A IDLE CURRENTS HARMONIC COMPOSITION OF POWER TRANSFORMER
نویسندگان
چکیده
منابع مشابه
Design and Control of a Novel hybrid Active Power Filter based on Load Harmonic Currents Separation with the aim of DC-link voltage minimization in voltage source converter
This paper proposes a new hybrid active power filter, including voltage source converter (VSC) based active power filter and Thyristor Controllable LC Passive Filter (TCLC-HAPF) for eliminating harmonic load current components and compensating reactive power. This new structure which is based on the separation of high and low-frequency components of load current idea can reduce the drawbacks of...
متن کاملFlexible Power Electronic Transformer for Power Flow Control Applications
This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...
متن کاملReasoning about Composition: A Predicate Transformer Approach
As interest in components and composition-related methods is growing rapidly, it is not always clear what the goals (and the corresponding difficulties) actually are. If composition is to become central in the future of software engineering, we need to better identify the fundamental issues that are related to it, before we attempt to solve them as they occur in object-oriented systems or in co...
متن کاملRecent Power Transformer Technology
Power transformers are essential components of substation equipment for the efficient and stable operation of electric power systems. There is demand for transformers with lower price and higher reliability. In addition, depending upon the onsite conditions, such as narrow roads, mountainous areas or highly congested urban areas, harmony with the surrounding environment is required throughout s...
متن کاملDesign of Delta Primary - Transposed zigzag Secondary (DTz) Transformer to Minimize Harmonic Currents on the Three-phase Electric Power Distribution System
The delta primary transposed zigzag secondary (DTz) transformer has been designed and used to reduce the bad impacts of the harmonic in the distribution power system. The DTz transformer is constructed with delta connection in primary winding and the three transposed windings at the different core legs of secondary winding. The harmonic reduction method of the DTz transformer applies two basic ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electrical Engineering and Power Engineering
سال: 2019
ISSN: 2521-6244,1607-6761
DOI: 10.15588/1607-6761-2019-1-4