A high quality bent crystal monochromator based on asymmetric Laue geometry
نویسندگان
چکیده
منابع مشابه
Characterization of a bent Laue double-crystal beam-expanding monochromator
A bent Laue double-crystal monochromator system has been designed for vertically expanding the X-ray beam at the Canadian Light Source's BioMedical Imaging and Therapy beamlines. Expansion by a factor of 12 has been achieved without deteriorating the transverse coherence of the beam, allowing phase-based imaging techniques to be performed with high flux and a large field of view. However, preli...
متن کاملDevelopment of a bent Laue beam-expanding double-crystal monochromator for biomedical X-ray imaging
The Biomedical Imaging and Therapy (BMIT) beamline at the Canadian Light Source has produced some excellent biological imaging data. However, the disadvantage of a small vertical beam limits its usability in some applications. Micro-computed tomography (micro-CT) imaging requires multiple scans to produce a full projection, and certain dynamic imaging experiments are not possible. A larger vert...
متن کاملapplication of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولHigh-resolution Laue-type DuMond curved crystal spectrometer.
We report on a high-resolution transmission-type curved crystal spectrometer based on the modified DuMond slit geometry. The spectrometer was developed at the University of Fribourg for the study of photoinduced X-ray spectra. K and L X-ray transitions with energies above about 10 keV can be measured with an instrumental resolution comparable to their natural linewidths. Construction details an...
متن کاملA computer method for determining by least squares gamma ray relative intensities using a bent-crystal monochromator
A method of measuring gamma-ray relative intensities was developed which used a germanium .bent-crystal spectrometer as a monochromator. The response function of a Nai detector to the essentially monoenergetic gamma rays, obtained from the diffracted beam of the spectrometer, was recorded in a multichannel analyzer. The composite spectrum due to all the gamma rays was then recorded in the analy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Crystallographica Section A Foundations of Crystallography
سال: 2005
ISSN: 0108-7673
DOI: 10.1107/s0108767305093955