A high-accuracy working standard for absolute pressure from 5 kPa to 130 kPa
نویسندگان
چکیده
منابع مشابه
Final Report on the Key Comparison CCM.P-K4.2012 in Absolute Pressure from 1 Pa to 10 kPa.
The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Ins...
متن کاملA New Method to Calculate the Absolute Amount of High-Pressure Adsorption of Supercritical Fluid
In the paper we developed a new method to determine the absolute amount of adsorption. This method relies on the excess adsorption isotherm and the density profile in the pore of one material. To compute the density profile and decrease complex calculation of obtaining the absolute amount of adsorption we introduced Simplified Local-Density (SLD) model. A few of appropriate parameters were ...
متن کاملA Double-Primary Dead-Weight Tester for Pressures (35–175) kPa in Gage Mode
Primary pressure standards in the atmospheric pressure range are often established using mercury manometers. Less frequently, controlled-clearance dead-weight testers in which one component (normally the piston) has been dimensionally measured have also been used. Recent advances in technology on two fronts i) the fabrication of large-diameter pistons and cylinders with good geometry; and ii) t...
متن کاملPredive sauna and venous gas bubbles upon decompression from 400 kPa.
INTRODUCTION This study investigated the influence of a far infrared-ray dry sauna-induced heat exposure before a simulated dive on bubble formation, and examined the concomitant adjustments in hemodynamic parameters. METHODS There were 16 divers who were compressed in a hyperbaric chamber to 400 kPa (30 msw) for 25 min and decompressed at 100 kPa x min(-1) with a 4-min stop at 130 kPa. Each ...
متن کاملAnalysis of clinical outcomes of linear vs. deep stop decompression from 3.5 to 6 atmospheres absolute (350 - 600 kpa) in awake rats.
UNLABELLED Recreational divers are introducing "deep stops" at half the depth (HD-DS) to reduce the risk of spinal DCS with only Doppler evidence to support it. Therefore this research was designed to show the effect of an HD-DS on spinal DCS manifestations by evaluating whether: (1) air diving-induced spinal DCS could be produced in awake, freely moving rats at 3.5-6.0 atm abs (350-600 kPa); a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Metrology and Quality Engineering
سال: 2017
ISSN: 2107-6847
DOI: 10.1051/ijmqe/2017020