A Fully Automatic Calibration System for Hydrometers in NIM

نویسندگان

چکیده

Abstract Hydrometers are widely used in industry for liquid density measurement. It is important to achieve rapid and high accuracy calibration hydrometers. Based on the Archimedes principle, a fully automatic hydrometer system NIM was designed using Cuckow’s method. The of n -tridecane (C 13 H 28 )is calibrated with 441 g high-purity fused silica ring as solid standard. buoyancy measured by static weighing resolution 0.01 mg. alignment between surface scale achieved lifting platform positioning 10 μm. According value air liquid, correction at different scales calculated. Hydrometer covering full range (650–1500) kg/m 3 can be without changing liquid. Taking data PTB reference, experimental show that measurement uncertainty this better than 0.3 division ( k = 2).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fully Automatic Endoscope Calibration for Intraoperative Use

As of today endoscopes have been only used as a keyhole to look inside the human body. Our goal is to enhance the endoscope to a full imaging device providing better quantitative and qualitative data. Possible applications for such an enhanced endoscope are referencing, navigation and 3D visualization during endoscopic surgery. To obtain accurate results, a reliable and fully automatic calibrat...

متن کامل

A fully automatic calibration procedure for freehand 3D ultrasound

This paper describes a novel method for calibration of freehand three-dimensional (3D) ultrasound. A position sensor is mounted on a conventional ultrasound probe, thus the set of B-scans can be localized in 3D, and can be compounded into a volume. The calibration process aims at determining the transformation (translations, rotations, scaling) between the coordinates system of images and the c...

متن کامل

An Improved High-Precision Calibration Procedure For Reference Standard Hydrometers

This pape r describes a me thod of calibra ting hydromete rs whic h. a lthoug h no more accurate tha t the technique used he re tofore at the Na tiona l Burea u of S ta nd a rds, reduces calibration time from se ve ral days to a few hours. The p rocedure is based upon eas ily measured h yd rome ter we ight , s tem sca le geometry, and flotat ion leve l measurement s a t onl y one liquid density...

متن کامل

Fully Automatic Camera Calibration Using Self- Identifying Calibration Targets

Determining camera calibration parameters is an essential step in most computer vision endeavors; it is a time-consuming task despite the availability of calibration algorithms and software. A set of point correspondences between points on the calibration target and the camera image(s) must be found, usually a manual or manually guided process. Two commonly used calibration tools are implementa...

متن کامل

 A novel approach to automatic position calibration for pixelated crystals in gamma imaging

Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Mapan-journal of Metrology Society of India

سال: 2021

ISSN: ['0974-9853', '0970-3950']

DOI: https://doi.org/10.1007/s12647-020-00426-w