A FLUORESCENCE PHOSPHATE SENSOR BASED ON POLY(GLYCIDYL METHACRYLATE) MICROSPHERES WITH ALUMINIUM-MORIN
نویسندگان
چکیده
منابع مشابه
Preparation and optical properties of indium tin oxide/epoxy nanocomposites with polyglycidyl methacrylate grafted nanoparticles.
Visibly highly transparent indium tin oxide (ITO)/epoxy nanocomposites were prepared by dispersing polyglycidyl methacrylate (PGMA) grafted ITO nanoparticles into a commercial epoxy resin. The oleic acid stabilized, highly crystalline, and near monodisperse ITO nanoparticles were synthesized via a nonaqueous synthetic route with multigram batch quantities. An azido-phosphate ligand was synthesi...
متن کاملControlled Release Ammonio Methacrylate Copolymer-Based Microspheres of Oxypentifylline
The objective of this work was to formulate and evaluate a controlled-release Oxypentifylline microspheres that fulfill the requirements for extended release medications using Ammonio Methacrylate Copolymer RS100 as polymeric material. The microsphere were prepared by quasiemulsion solvent diffusion technique. The effect of process variables such as drug to polymer ratio, stirring rate, and con...
متن کاملPhosphate-selective fluorescent sensing microspheres based on uranyl salophene ionophores.
Optical dihydrogen phosphate-selective sensors that function on the basis of bulk optode principles and are based on two different uranyl salophene ionophores are reported here for the first time. The influence of the optode composition and measuring conditions such as sample pH on the optode response are characterized, along with sensor selectivity and long-term stability. Three plasticizers o...
متن کاملIntravascular Hemolysis Due to Glucose‐6‐Phosphate Dehydrogenase Deficiency in a Patient with Aluminium Phosphide Poisoning
Aluminium Phosphide poisoning and glucose‐6‐phosphate dehydrogenase deficiency are two commonly seen clinical presentations in Iran. However, hemolysis associated with Aluminium Phosphide poisoning is very rare. We report a case of concurrent Aluminium Phosphide poisoning and glucose‐6‐phosphate dehydrogenase deficiency in a 24 year old man presenting with intravascular hemolysis. Key words...
متن کاملLocalization of aluminium in the maize root apex: can morin detect cell wall-bound aluminium?
Morin is a fluorochrome which forms a fluorescent complex with aluminium (Al) and is thus used to localize Al in plant tissues. However, reports about the cellular distribution of Al-apoplastic versus symplastic-based on morin staining are often conflicting. The objective of this work was to investigate whether Al localization with morin staining can show the proper cellular distribution of Al....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Malaysian Journal of Analytical Science
سال: 2016
ISSN: 1394-2506,1394-2506
DOI: 10.17576/mjas-2016-2004-02