A flow sensor exploiting magnetic fluids

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow control of magnetic fluids exposed to magnetic fields

The description of flow in ferrohydrodynamics (Rosensweig, 1985) is based on a combination of equations, namely the continuity equation, the Navier-Stokes equation, the Maxwell equations and particular equations for the magnetization. Since the different models to describe the relaxation of magnetization differ, the adequate one has yet to be identified. By comparing experimental and simulation...

متن کامل

Magnetic Nanoparticles in Magnetic Fluids

Magnetic fluids are stable colloidal systems of fine single-domain magnetic particles (for example Fe3O4, γ-Fe2O3, Co, MnFe2O4, etc.) that are suspended in liquid carrier such as water, mineral oil, damping oil, paraffin, kerosene and so on. The properties of magnetic fluids are well controlled by external magnetic field that gives broad possibilities for technical and biomedical applications. ...

متن کامل

Novel magnetic field sensor based on magnetic fluids infiltrated dual-core photonic crystal fibers

Novel magnetic field sensor based on magnetic fluids infiltrated dual-core Photonic Crystal Fibers (PCFs) is proposed in this paper. Inside the cross-section of the designed PCFs, the two fiber cores filled with magnetic fluids (Fe3O4) are separated by an air hole, and then form two independent waveguides with mode coupling. The mode coupling under different magnetic field strength is investiga...

متن کامل

Characterisation of magnetic fluids

One method suitable for the accurate characterisation of magnetic fluids is by the measurement of the frequency-dependent, complex susceptibility, χ(ω) = χ′(ω) − iχ′′(ω). Such measurements enable data on, relaxation mechanisms, ferromagnetic resonance, stochastic resonance, non-linear properties, magnetic losses and the signal-to-noise ratio (SNR) of these colloidal nano-particle systems to be ...

متن کامل

A magnetic tunnel to shelter hyperpolarized fluids.

To shield solutions carrying hyperpolarized nuclear magnetization from rapid relaxation during transfer through low fields, the transfer duct can be threaded through an array of permanent magnets. The advantages are illustrated for solutions containing hyperpolarized (1)H and (13)C nuclei in a variety of molecules.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Procedia Engineering

سال: 2011

ISSN: 1877-7058

DOI: 10.1016/j.proeng.2011.12.139