A fast low-noise charged-particle CVD diamond detector

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

p-CVD diamond heavy-ion beam detector with integrated electronics

For the new ToF Barrel of FOPI, [1], a new beam detector based on polycrystalline-CVD diamond was developed. The new device replaces the existing beam monitoring system which comprise a ToF Start detector and a beam-halo detector, both built from plastic scintillator material. However, since the employed diamonds are not sensitive to minimum ionizing particles the new device can be used efficie...

متن کامل

A Fast, Robust, Automatic Blink Detector

Introduction “Blink” is defined as closing and opening of the eyes in a small duration of time. In this study, we aimed to introduce a fast, robust, vision-based approach for blink detection. Materials and Methods This approach consists of two steps. In the first step, the subject’s face is localized every second and with the first blink, the system detects the eye’s location and creates an ope...

متن کامل

A Bayesian method to estimate the neutron response matrix of a single crystal CVD diamond detector

Detectors made from artificial chemical vapor deposition (CVD) single crystal diamond are very promising candidates for applications where high resolution neutron spectrometry in very high neutron fluxes is required, for example in fusion research. We propose a Bayesian method to estimate the neutron response function of the detector for a continuous range of neutron energies (in our case, 10 M...

متن کامل

Charged particle detectors made of single-crystal diamond

E. Berdermann 1, 4, M. Ciobanu, S. H. Connell, A. M. O. D. da Costa, L. Fernandez-Hernando, A. Oh 4, and J. P. F. Sellschop† 1 Gesellschaft für Schwerionenforschung (GSI) Darmstadt, Planckstrasse 1, 64291 Darmstadt, Germany 2 Schonland Research Institute for Nuclear Science, University of the Witwatersrand, Johannesburg, South Africa 3 CERN, European Organization for Nuclear Research, Geneva, S...

متن کامل

Synthetic-diamond detectors for charged-particle beams dosimetry

Hadron cancer-therapy with high-energetic heavy-ions (HI) as available at the SIS facility at GSI Darmstadt [1] as well as the research with beams stopped in biological material as realized at the UNILAC at GSI in general require the precise knowledge of beam conditions and its composition as well as the applied dose within less than 1% in most cases. At these sites beam preparation, its applic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Nuclear Science

سال: 2004

ISSN: 0018-9499