A fast and robust reference current generation algorithm for three-phase shunt active power filter
نویسندگان
چکیده
The identification of the reference currents constitutes an important part control active power filter. This requires accurate estimation frequency, phase, and proper extraction load current harmonics. makes modeling more difficult requests a rigorous selection techniques to be used. For sake simplicity, direct method is motivated by need for simplicity flexibility than existing such as instantaneous theory diphase method. However, this robust phase-locked loop extract unity voltages controller estimate magnitude source current. To end, paper proposes hybrid (HPLL) good option mainly because 1) it achieves zero phase error under frequency drifts, 2) Fast dynamic response, 3) totally block DC offset, 4) From point view, type 1 system which results in high stability margin. best authors’ knowledge, HPLL has not been used filter yet. Furthermore, neural PI regulator Simulation show efficiency proposed technique illustrate all its interesting features. comparison, compared other advanced techniques.
منابع مشابه
A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کاملPV Based Three-Level NPC Shunt Active Power Filter with Extended Reference Current Generation Method
This paper proposes an extended reference current calculation method for the PV based three-level neutral point clamped (NPC) shunt active power filter (SAPF). Shunt active power filter demands a source of energy for compensating the current based distortions, which utilizes the photovoltaic array with DC-DC boost converter as a source of DC power. The shunt connected inverter controls the DC l...
متن کاملA Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation
Power quality issues are becoming a major concern of today's power system engineers. Shunt active power filter (SAPF) is one of the effective means for harmonic current compensation in electrical power system. The performance and dynamic characteristics of a three-phase SAPF with a simple control algorithm is presented and analyzed in this paper. This algorithm operates at fixed switching frequ...
متن کاملCompensation Strategies for Shunt Active Power Filter in Single- and Three-Phase Systems: Different Formulation, Comparison and Evaluation
متن کامل
Modelling of Three-phase Shunt Hybrid Active Power Filter
The three-phase Shunt hybrid APF topology for harmonic mitigation in low and medium voltage power distribution systems consists of a VSI based three phase shunt active filter (SAF) and tuned passive filters (TPF) connected in parallel with the load. This chapter discusses the modelling of shunt active filter and design of filter interfacing inductor, DC bus capacitor, tuned passive filters. It ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Power Electronics and Drive Systems
سال: 2021
ISSN: ['2722-2578', '2722-256X']
DOI: https://doi.org/10.11591/ijpeds.v12.i1.pp121-129