A Dosimetric Comparison of Intensity-Modulated Proton Therapy, Volumetric-Modulated Arc Therapy, and 4π Non-Coplanar Intensity-Modulated Radiation Therapy for a Patient with Parameningeal Rhabdomyosarcoma
نویسندگان
چکیده
منابع مشابه
A Dosimetric Comparison of Intensity-Modulated Proton Therapy, Volumetric-Modulated Arc Therapy, and 4π Non-Coplanar Intensity-Modulated Radiation Therapy for a Patient with Parameningeal Rhabdomyosarcoma
Rhabdomyosarcoma (RMS) is the most common soft tissue sarcoma in children and manifests as two major histological subtypes: embryonal and alveolar. The five-year local failure rate for RMS at parameningeal sites (middle ear, mastoid region, nasal cavity, etc.) is around 17% despite multiple Intergroup Rhabdomyosarcoma Study Group (IRS) trials conducted to determine the optimal radiation treatme...
متن کاملIntensity modulated radiation therapy versus volumetric intensity modulated arc therapy
The advanced developments in external beam radiation therapy (EBRT) over the past few decades have improved dose conformity to the target while minimizing dose to the surrounding organs at risk (OAR). Intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) are two commonly used EBRT techniques to treat cancer. In sliding window (SW) or dynamic IMRT, each radiati...
متن کاملVolumetric intensity-modulated arc therapy vs conventional intensity-modulated radiation therapy in nasopharyngeal carcinoma: a dosimetric study
Dosimetric comparisons between RapidArc (RA) and conventional Intensity-Modulated Radiation Therapy (IMRT) techniques for nasopharyngeal carcinoma (NPC) were performed to address differences in dose coverage of the target, sparing of organs-at-risk (OARs), delivery of monitor units (MUs) and time, to assess whether the RA technique was more beneficial for treatment of NPC. Eight NPC patients (S...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Cureus
سال: 2017
ISSN: 2168-8184
DOI: 10.7759/cureus.1673