A dose gradient analysis tool for IMRT QA

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A dose‐gradient analysis tool for IMRT QA

The use of intensity-modulated radiation therapy (IMRT) has led to an increase in the number of complex fields that require measurement and comparison to calculated dose distributions in 2D. Current dose-evaluation techniques, including isodose line comparisons, displays of the dose difference between calculated and measured distributions, and distance-to-agreement (DTA) comparisons, are useful...

متن کامل

A survey on planar IMRT QA analysis

Quality assurance (QA) systems for intensity-modulated radiation therapy (IMRT) have become standard tools in modern clinical medical physics departments. However, because formalized industry standards or recommendations from professional societies have yet to be defined, methods of IMRT QA analysis vary from institution to institution. Understanding where matters stand today is an important st...

متن کامل

Confidence limits for patient‐specific IMRT dose QA: a multi‐institutional study in Korea

This study aims to investigate tolerance levels for patient-specific IMRT dose QA (DQA) using the confidence limits (CL) determined by a multi-institutional study. Eleven institutions participated in the multi-institutional study in Korea. A total of 155 DQA measurements, consisting of point-dose differences (high- and low-dose regions) and gamma passing rates (composite and per-field) for IMRT...

متن کامل

A Varian DynaLog file‐based procedure for patient dose‐volume histogram‐based IMRT QA

In the present study, we describe a method based on the analysis of the dynamic MLC log files (DynaLog) generated by the controller of a Varian linear accelerator in order to perform patient-specific IMRT QA. The DynaLog files of a Varian Millennium MLC, recorded during an IMRT treatment, can be processed using a MATLAB-based code in order to generate the actual fluence for each beam and so rec...

متن کامل

Efficient independent planar dose calculation for FFF IMRT QA with a bivariate Gaussian source model

The aim of this study is to perform a direct comparison of the source model for photon beams with and without flattening filter (FF) and to develop an efficient independent algorithm for planar dose calculation for FF-free (FFF) intensity-modulated radiotherapy (IMRT) quality assurance (QA). The source model consisted of a point source modeling the primary photons and extrafocal bivariate Gauss...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Clinical Medical Physics

سال: 2005

ISSN: 1526-9914

DOI: 10.1120/jacmp.2024.25338