A Distance Detector with a Strip Magnetic MOSFET and Readout Circuit
نویسندگان
چکیده
منابع مشابه
A Distance Detector with a Strip Magnetic MOSFET and Readout Circuit
This paper presents a distance detector composed of two separated metal-oxide semiconductor field-effect transistors (MOSFETs), a differential polysilicon cross-shaped Hall plate (CSHP), and a readout circuit. The distance detector was fabricated using 0.18 μm 1P6M Complementary Metal-Oxide Semiconductor (CMOS) technology to sense the magnetic induction perpendicular to the chip surface. The di...
متن کاملCharge Division Readout of a Two-dimensional Germanium Strip Detector
Germanium strip detectors combine superior spectroscopy typical of germanium detectors with good spatial resolution. Our work has been to develop a 2-dimensional position readout of a 5 5 strip X-Y detector. The prototype device uses two capacitive charge division strings. Each string is read{out by two 13-bit ADCs, one on each end of the string. The four data channels are stored as an event li...
متن کاملCMOS Readout System for a Double-sided Germanium Strip Detector
A wide variety of applications require a hard Xray or gamma ray detector which combine both good spatial resolution and energy resolution. Double-sided solid-state strip detectors provide this capability. We report on the development of CMOS electronics designed for photon detection with strip detectors. These electronics include a low noise preamplifier, semi-gaussian shaping amplifier, discri...
متن کاملThe OPAL Silicon Strip Microvertex Detector with Two Coordinate Readout
The OPAL experiment at the CERN LEP collider recently upgraded its silicon strip microvertex detector from one coordinate readout ( only) to two coordinate readout ( and z). This allows three dimensional vertex reconstruction and should improve lifetime measurements as well as b quark jet identi cation. This paper describes the new microvertex detector system with emphasis on the novel techniqu...
متن کاملPeripheral dose measurement with a MOSFET detector.
The accuracy of a MOSFET dosimetry system with respect to peripheral therapeutic doses from high-energy X-rays has been evaluated. The results have been compared with ionisation chamber measurements in the same peripheral regions of the beam. For 6 MV and 18 MV X-ray beams, the MOSFET system in the high-sensitivity mode produces reproducibility of dose measurement with relative standard deviati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2017
ISSN: 1424-8220
DOI: 10.3390/s17010126