A direct radioimmunoassay for serum 11-deoxycortisol.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A direct radioimmunoassay for serum 11-deoxycortisol.

A simple direct radioimmunoassay for 11-deoxycortisol in serum is described. A new type of bridge heterologous 125I labeled 11-deoxycortisol was prepared and was applied to the direct radioimmunoassay. Low and high levels of 11-deoxycortisol in serum were sensitively determined by the direct radioimmunoassay.

متن کامل

Improved radioimmunoassay for 11-deoxycortisol (compound S) in plasma.

We describe a radioimmunoassay for 11-deoxycortisol (Compound S) that involves preliminary chromatography on Sephadex LH-20, to isolate 11-deoxycortisol from crossreacting structurally related steroids. Pools with means of 3.4, 12.9, and 69.9 micrograms/L gave intra-assay coefficients of variation of 9.7, 9.6, and 11.4%, respectively; pools with means of 4.6, 27, and 95 micrograms/L gave inter-...

متن کامل

Parallel radioimmunoassay for plasma cortisol and 11-deoxycortisol.

We describe a direct, rapid, and specific procedure for the parallel radioimmunoassay for cortisol and 11-deoxycortisol in plasma. The plasma sample is used directly, after heat inactivation of the natural cortisol-binding protein. The radioimmunoassay utilizes antibodies generated in rabbits by steroids congugated at their 3-oxo position to thyroglobulin. Ammonium sulfate is used to separate b...

متن کامل

Polarization fluoroimmunoassay of 11-deoxycortisol in serum and saliva.

We developed polarization fluoroimmunoassays for 11-deoxycortisol in serum and saliva. To avoid interfering factors, the steroid was initially extracted from the biological fluids with dichloromethane. Assays could then be completed without any further separation procedures or need to correct for blank signals. The serum assay was suitable for following the response to the metyrapone test and r...

متن کامل

Direct radioimmunoassay for serum estriol during pregnancy.

I describe an assay for serum estriol during pregnancy, which does not require prior extraction or chromatography of the serum. Fifty microliters of 20-fold diluted serum can be assayed to detect as little as 20 pg of estriol. For a 20 mug/liter serum estriol concentration the CV was 16%; for 100 mug/liter concentration it was 5%. There was no significant interference by serum "binding" protein...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: RADIOISOTOPES

سال: 1988

ISSN: 1884-4111,0033-8303

DOI: 10.3769/radioisotopes.37.15