A direct power control of a DFIG based-WECS during symmetrical voltage dips
نویسندگان
چکیده
منابع مشابه
Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
متن کاملDynamic Performance Of DFIG Based WECS Under Different Voltage Sag
At the present time Doubly Fed Induction Generator (DFIG) based wind energy conversion systems are widely used for large wind power plants. DFIG offers many advantages for instance reduced rating power converter, low cost and reduced losses with the better efficiency, easy in realization of power factor correction schemes, variable speed operation and four quadrants active and reactive power co...
متن کاملImprovement of Transient Voltage Profile Using Power Control of the DFIG-Based Wind Farm Under Severe Voltage Dip Event
Improving transient voltage stability is one of the most important issues that must be provided by doubly fed induction generator (DFIG)-based wind farms (WFs) according to the grid code requirement. This paper proposes adjusted DC-link chopper based passive voltage compensator and modified transient voltage controller (MTVC) based active voltage compensator for improving transient voltage stab...
متن کاملLow voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips
This paper proposes a competent and effective scheme to enhance the ride-through capability of DFIGbased wind turbines under unbalanced voltage dip conditions. The proposed method is realized through joint use of the rotor-side converter control and a three-phase stator damping resistor (SDR) placed in series with the stator windings. By means of an asymmetrical SDR idea, during the unbalanced ...
متن کاملA Combined Vector and Direct Power Control for AC/DC/AC Converters in DFIG Based Wind Turbine
The doubly-fed generators (DFIG) have clear superiority for the applications of large capacity and limited-range speed control case due to the partially rated inverter, lower cost and high reliability. These characteristics enable the doubly-fed wound rotor induction machine to have vast applications in wind-driven generation.In this paper Combined Vector and direct power control (CVDPC) strate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Protection and Control of Modern Power Systems
سال: 2020
ISSN: 2367-2617,2367-0983
DOI: 10.1186/s41601-019-0148-y