A digital integrator for graphite tube furnace atomic absorption spectrophotometry

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid ultramicro direct determination of erythrocyte lead concentration by atomic absorption spectrophotometry, with use of a graphite-tube furnace.

We describe a convenient, sensitive, accurate, precise and direct method for lead analysis in blood by use of the graphite-tube furnace with an atomic absorption spectrophotometer. Advantages of this proposed method are the ultramicro sample size and the minimal sample preparation required. Interferences by the major cations and anions in blood were studied and minimized. Anticoagulants examine...

متن کامل

Anodic stripping voltammetry compared with graphite furnace atomic absorption spectrophotometry for blood lead analysis.

According to a recent CDC report, blood lead concentrations in 1 000 000 US children are at values associated with irreversible damage to health (1 ). The effects of chronic lead poisoning on the developing nervous systems have been well documented (2 ), with children in inner city neighborhoods, where older housing stocks have deteriorating lead paint, most vulnerable (3 ). Accurate screening ...

متن کامل

Determination of aluminum in biological samples by atomic absorption spectrophotometry with a graphite furnace.

Aluminum, generally considered non-essential and non-toxic, may accumulate in toxic amounts in the brain in cases of chronic renal failure. We describe a procedure for its analysis in biological fluids by atomic absorption spectrophotometry with a graphite furnace. No sample preparation is required and the procedure is sensitive at the appropriate concentrations. A sample of serum or urine is p...

متن کامل

Analysis of Low Lead and Cadmium Concentrations in Soil Extracts by Graphite Furnace Atomic Absorption Spectrophotometry

An analytical procedure was derived to provide an accurate measurement of low lead (Pb) and cadmium (Cd) concentrations in soil extracts using graphite furnace atomic absorption spectrometry (GFAAS). Based on peak area measurements and with background correction, the use of 2% phosphoric acid as chemical modifier enables the GFAAS to give measurements of Pb and Cd concentration as low as 3 fLg ...

متن کامل

Determination of cadmium in blood and urine by graphite furnace atomic absorption spectrophotometry.

カ ド ミウム(Cd)作 業者 のCd曝 露 指 標 として,血 液 お よび 尿 中Cdの 測 定 が有 効 であ り1),こ れ ら生体 試 料 中 のCd測 定方 法 と しては黒 鉛 炉原 子 吸 光法2~6)が 広 く 用 い られ て い る.こ の方 法 に よるCd定 量 では, Cdお よび そ の化合 物 の融点 が低 いた め,原 子 化 段階 以 前 での 揮 散 が問 題 で あ り,対 策 と して適 当な 干渉 抑制 剤 を添 加 す る ことに よ り,揮 散 を 抑制 す る方 法 が と られ て い る. Cd定 量 に 対 して は, HNO32-4), NH4H2PO43,4), NH4NO33-5), NH4F4,6)お よびPd(NO3)25)な どが 干渉 抑制 剤 と して提 唱 され て い る.血 中Cd(Cd-B)の 定量 に従...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BUNSEKI KAGAKU

سال: 1978

ISSN: 0525-1931

DOI: 10.2116/bunsekikagaku.27.8_t30