A detailed hydrothermal investigation of a helical micro double-tube heat exchanger for a wide range of helix pitch length

نویسندگان

چکیده

The present study was numerically inquired the heat transfer performance and fluid flow characteristic of a helical micro double-tube exchanger (HMDTHX) using finite volume method. tube length considered to be constantly equal 30 mm, 12 different configurations were modeled by changing in turn number pitch (P) for Reynolds numbers 50, 100, 150, 200. findings indicated that would enhance applying any helix angle straight tube. However, it had an optimum point which varied (Re). Rising Re caused overall coefficient (OHTC), pressure drop, pumping power augment all cases. Increasing P reduced OHTC, maximum points between = 0.5 3. Maximum (OHTC) enhancement 45% 200 2. Also, effectiveness 11.5% 2 Moreover, 42% increment achieved power, friction factor at Shear stress 100 showed values are almost same 1. Then increasing P, shear decreases. While, is seen temperature distribution same, but difference average temperature, 3.2 K tubes. Finally, investigating velocity contour, determined secondary through HMDTHX, affected centrifugal force, existed, enhancing turbulency rate.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Heat Transfer Coefficient Enhancement for CuO/TiO2 Nanocomposite in a Tube Heat Exchanger

In order to improve the efficiency and rate of heat transfer in heat exchangers, various techniques such as increasing the heat transfer coefficient are proposed. This study is devoted to the investigation of heat transfer coefficient variations due to the addition of CuO, TiO2 and CuO/TiO2 nanoparticles into a shell and tube heat exchanger. CuO/TiO2 nanocomposite was synthesized using mechanic...

متن کامل

An experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger

One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...

متن کامل

An experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger

One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...

متن کامل

Measurement of Local Convective Heat Transfer Coefficient of Alumina-Water Nanofluids in a Double Tube Heat Exchanger

Heat transfer coefficient and thermal efficiency of γ-Al2O3/water nanofluids flowing through a double tube heat exchanger were experimentally investigated. The nanoparticles were well dispersed in distilled water at 0.05–0.15 %vol. A large number of experiments were performed at different fluid flow rates under turbulent flow regime (18,000<Re<40,000) and various nanofluid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Case Studies in Thermal Engineering

سال: 2021

ISSN: ['2214-157X']

DOI: https://doi.org/10.1016/j.csite.2021.101413