A DC Series Arc Fault Detection Method Using Line Current and Supply Voltage

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arc Fault Detection in Low Voltage DC System Using Wavelet Transform

The main objective of this paper to detect an arc fault occurring in a low voltage dc system using wavelet transform. As we know arc faults plays a major role in an electrical power system, due to this fire, shocking hazard or system failure of the electrical system or equipment can be happen. It’s very challenging to detect arc fault in a dc system because unlike a ac system a dc system cannot...

متن کامل

Research on Low-voltage Series Arc Fault Detection Method Based on Least Squares Support Vector Machine

Arc fault is one of the important reasons of electrical fires. In virtue of cross talk, randomness and weakness of series arc faults in low-voltage circuits, very few of techniques have been well used to protect loads from series arc faults. Thus, a novel detection method based on support vector machine is developed in this paper. If series arc fault occurs, high frequency signal energy in circ...

متن کامل

High Voltage Dc-dc Converter Using a Series Stacked Topology

The converter will be used to charge a large battery bank as well as supplying power to a constant power absorbing load. It will have to operate in either constant current mode or constant voltage mode, depending on the state of charge of the battery bank. Peak current mode control is implemented to give this functionality to the converter. The series stack topology also allows interleaved swit...

متن کامل

Series Resonance Based Fault Current Limiter with Controlling The Point of Common Coupling Voltage

This paper proposes a novel Fault Current Limiter (FCL) for the application on distribution networks to control voltage sags at the Point of Common Coupling (PCC) during faults. This new FCL is based on series resonance including resonance transformer and series capacitor. So, by proper design of the series resonance LC tank, the fault current is limited to an acceptable level. The FCL operatio...

متن کامل

Current Directional Protection of Series Compensated Line Using Intelligent Classifier

Current inversion condition leads to incorrect operation of current based directional relay in power system with series compensated device. Application of the intelligent system for fault direction classification has been suggested in this paper. A new current directional protection scheme based on intelligent classifier is proposed for the series compensated line. The proposed classifier uses ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Access

سال: 2020

ISSN: 2169-3536

DOI: 10.1109/access.2019.2963500