A continuous interference-filter monochromator
نویسندگان
چکیده
منابع مشابه
Construct a monochromator from a single interference filter.
Fig. I Lomb i incidenco incidenc irchers in the behavioral and visual sciences The upper panel of Figure 1 shows the output of a tly need a source of monochromatic light whose Bausch and Lomb 641-nm interference filter at five Lgth can be varied. The purpose of this note is different angles of incidence. The peak wavelength of ribe principles and construction of a reliable the distribution move...
متن کاملAn Interference-Filter Monochromator System for the Irradiation of Biological Material.
The determination of action spectra for biological photoreactions requires that large areas be irradiated uniformly at high intensities and with narrow band widths for the resolution of spectral details: When the material is changing irreversibly with time or when long irradiation periods are required, it may be necessary to irradiate samples at ten or more different points in the spectrum simu...
متن کاملAssessment of a Continuous Electrocoagulation on Turbidity Removal from Spent Filter Backwash Water
Background & Aims of the Study: Spent filter backwash water (SFBW) consists of 1-5% of the total treated water typically and it has a high turbidity. Because of the scarcity of water resources and in order to prevent the environmental contamination, effluent treatment of rapid sand filter backwashing is unavoidable. One of the new technologies for removal of turbidity from the ...
متن کاملInterference Mitigation of Replay Attacks in GPS Receiver using of Finite Impulse Response Filter
The vulnerability of civil GPS receiver to interference may be intentional or unintentional. Among all types of interference, replay attack intended as the most dangerous intentional one. The signal structure of replay attack is almost the same with the satellite signal. The interference effects can be reduce with the design of an appropriate filter in the receiver. This paper presents two meth...
متن کاملCalibration of a monochromator using a lambdameter
The standard procedure for wavelength calibration of monochromators in the visible and near infrared wavelength range uses low-pressure gas discharge lamps with spectrally well-known emission lines as primary wavelength standard. The calibration of a monochromator in the wavelength range of 350 to 2500 nm usually takes some days due to the huge number of single measurements necessary. The useab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Behavior Research Methods & Instrumentation
سال: 1974
ISSN: 1554-351X,1554-3528
DOI: 10.3758/bf03200282