A Computer System for Multiparameter Pulse Height Analysis and Control
نویسندگان
چکیده
منابع مشابه
Alcator C - Mod Soft X - Ray Pulse Height Analysis System
A pulse height analysis (PHA) system has been installed on the Alcator C-Mod magnetic confinement fusion experiment. The PHA utilizes a Si(Li) detector to measure soft X-rays in the 1-30 keV range with an energy resolution on the order of 100eV. A FASTComtec MCA-3 multichannel analyzer allows integration times of ims while the PHA supports counting rates of up to 80kHz. The thermal electron tem...
متن کاملفرآیند کنترل در سیستم کامپیوتری تهویه مطبوع airwasher environmental control system for intelligent buildings
در این پایان نامه با استفاده از تکنولوژی روز و امکانات داخل کشور طریقه اتوماسیون سیستم تاسیساتی یک کارخانه نساجی (کارخانه نساجی اطلس پود) همراه با منوهای مربوطه و توضیحات کامل برنامه نویسی و طراحی بلوک های برنامه و سایر قسمتهای برنامه ارائه گشته است. علاوه بر این، برنامه با نمونه آمریکایی آن مقایسه و مزیت های آن نسبت به آمریکایی توضیح داده شده است. همچنین تمامی بلوک های برنامه بصورت شماتیکی بطو...
15 صفحه اولComputer-Aided Control System Analysis
A variety of programs involving interactive computer graphics are available at Rensselaer Polytechnic Institute for the analysis and design of both univariable and multivariable control systems and for related instructional purposes. The principal features of these programs and the ways in which they are used in the curriculum are discussed.
متن کاملSafety Analysis of the Height Control System for the Elbtunnel
A new tunnel tube crossing the river Elbe has been built in Hamburg until the end of 2002. Therefore, a new height control system was required. A computer examines the signals from light barriers and overhead sensors to detect vehicles, which try to drive into a tube with insufficient height. If necessary, it raises an alarm that blocks the road. This paper describes the application of two safe...
متن کاملRapid screening for bacteriuria using a particle counter, pulse-height analyser, and computer.
A system for the rapid screening of urines for the presence of bacteriuria has been devised using a Coulter Counter Model ZBI linked to a multichannel pulse-height analyser (Coulter "Channelyser") with computer analysis of the output. In a series of 215 urines containing growth of a single pathogen of more than 100 x 10(6)/l (greater than 100 000/ml) satisfactory level of sensitivity (99.1%) wa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1972
ISSN: 0018-9499
DOI: 10.1109/tns.1972.4326587