A Computational Analysis of Squeaking Hip Prostheses
A ceramic-on-ceramic (CoC) hip prosthesis with clearance is modeled as a multibody dynamics system for the purpose of studying hip squeaking. A continuous contact force model provides the intrajoint forces developed at the hip joint. Friction effects due to the relative motion are also considered. A FFT analysis of the audible sounds from CoC hip acceleration is carried out to analyze hip squea...
متن کاملA review of squeaking in ceramic total hip prostheses
The occurrence of audible squeaking in some patients with ceramic-on-ceramic (CoC) hip prostheses is a cause for concern. Great effort has been dedicated to understand the mechanics of the hip squeaking to gain a deeper insight into factors contributing to sound emission from CoC hip articulation. Disruption of fluid-film lubrication and friction were reported as the main potential cause, while...
متن کاملHip Squeaking
The aim of the study was to analyze the incidence of squeaking with ceramic-onceramic total hip arthroplasty (THA) after 10 years of follow-up and the potential complications that could occur related to this phenomenon. One hundred THAs implanted between November 1999 and December 2000 were evaluated. Incidence of squeaking was investigated clinically with a questionnaire. Implant positioning w...
متن کاملThe squeaking hip: a cause for concern-disagrees.
Total hip arthroplasty with ceramic-on-ceramic bearing surfaces has demonstrated low wear with excellent clinical outcomes. More recently, concerns have surfaced because of the presence of audible squeaking in some ceramic-on-ceramic THA patients. The incidence of this phenomenon has been low and has infrequently required reoperation. The exact etiology of squeaking remains unclear but is likel...
متن کاملComputational simulation analysis for torus radius of edge contact in hip prostheses.
Stripe wear occurs when the components of hip prostheses move a sufficient distance laterally to contact the edge of the acetabular cup, causing abnormally high contact stresses. In this research, edge loading contact of prosthetic hip is analyzed in the most commonly used material pairs. The contact dimensions and maximal contact pressure are investigated in mutative normal edge loading with 3...