A Compliant PKM Mesomanipulator: Kinematic and Dynamic Analyses
نویسندگان
چکیده
منابع مشابه
Kinematic and Dynamic Analyses of the Orthoglide 5-axis
This paper deals with the kinematic and dynamic analyses of the Orthoglide 5-axis, a five-degree-of-freedom manipulator. It is derived from two manipulators: i) the Orthoglide 3-axis; a three dof translational manipulator and ii) the Agile eye; a parallel spherical wrist. First, the kinematic and dynamic models of the Orthoglide 5-axis are developed. The geometric and inertial parameters of the...
متن کاملKinematic Analysis and Optimization of a New Compliant Parallel Micromanipulator
In this paper, a new three translational degrees of freedom (DOF) compliant parallel micromanipulator (CPM) is proposed, which has an excellent accuracy of parallel mechanisms with flexure hinges. The system is established by a proper selection of hardware and analyzed via the derived pseudo-rigid-body model. In view of the physical constraints imposed by both the piezoelectric actuators and fl...
متن کاملFull Compliant Continuum Robotic Finger and Its Kinematic Model
Abstract– Different from the traditional rigid robots made by hard material such as metal, continuum robots are bionic mechanisms which feature high compliance and continuous shapechanging ability. A full compliant continuum robotic finger is proposed, which is driven by the compressed air inside its silicon rubber chamber and has a certain degree of grasping rigidity. By the moment equilibrium...
متن کاملDynamic Compliant Quadruped Walking
This paper presents a new dynamic walking controllers for quadrupedal robots with compliant legs. The algorithm implements a "walking bound" gait, (running bound without ight phase), requires only one actuator per leg at the hip, and commands a constant hip velocity during stance. The algorithm has been implemented successfully on our Scout II quadruped robot and has yielded stable walking for ...
متن کاملA scapular coordinate frame for clinical and kinematic analyses.
The aim of this study was to define a body-fixed coordinate frame for the scapula that minimises axes variability and is closely related to the clinical frame of reference. Medical images of 21 scapulae were used to quantify 14 different axes from identifiable landmarks. The plane of the blade of the scapula was defined. The orientations of the quantified axes were calculated. The angular relat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Mechanical Engineering
سال: 2010
ISSN: 1687-8140,1687-8140
DOI: 10.1155/2010/706023