A complex flow phantom for medical imaging: ring vortex phantom design and technical specification
نویسندگان
چکیده
منابع مشابه
Geometry Calibration Phantom Design for 3D Imaging
Most approaches to 3D x-ray imaging geometry calibration use some well-defined calibration phantom containing point markers. The calibration aims at minimizing the so-called re-projection error, i.e., the error between the detected marker locations in the acquired projection image and the projected marker locations based on the phantom model and the current estimate of the imaging geometry. The...
متن کاملA novel phantom design for brachytherapy quality assurance
Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...
متن کاملDesign and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging
Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...
متن کاملDevelopment of a universal medical X‐ray imaging phantom prototype
Diagnostic X-ray imaging depends on the maintenance of image quality that allows for proper diagnosis of medical conditions. Maintenance of image quality requires quality assurance programs on the various X-ray modalities, which consist of pro-jection radiography (including mobile X-ray units), fluoroscopy, mammography, and computed tomography (CT) scanning. Currently a variety of modality-spec...
متن کاملPhantom validation of 4D flow: independent validation of vortex ring volume quantification using planar laser-induced fluorescence
Cardiac MR group Lund, Dept. of Clinical Physiology, Lund University, Lund, Sweden Full list of author information is available at the end of the article Figure 1 Design and construction of the vortex ring flow phantom. a) 2D view of the flow rectifier and vortex ring tank. All measures are in millimeters (mm). b) 3D view of the flow rectifier and vortex ring tank. c) Pump design. A servo motor...