A comparison of treatment planning techniques for low-dose-rate (LDR) prostate brachytherapy

نویسندگان

چکیده

PurposeThe purpose of this study was to compare low-dose-rate prostate brachytherapy treatment plans created using three retrospectively applied planning techniques with delivered patients.Methods and MaterialsTreatment were on transrectal ultrasound (TRUS) scans for 26 patients. The technique dubbed 4D Brachytherapy applied, TRUS MRI obtain prostatic measurements required the associated webBXT online nomogram. Using a patient's scan create plan involving loose seeds also explored. Plans patients made an intraoperative seed TRUS-based technique. Prostate V100 (%), V150 D90 (Gy), rectum D0.1cc D2cc urethra D10 D30 volumes measured each patient. Statistical analysis used assess plans.ResultsProstate by significantly different. calculated nomogram TRUS- MRI-based not Compared plans, showed lower (Gy) values, higher (%) values values.ConclusionsTRUS-based similar dosimetry plans; rectal superior. can be integrated into workflow. overestimates number seeds.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the MIM Symphony treatment planning system for low‐dose‐rate‐ prostate brachytherapy

MIM Symphony is a recently introduced low-dose-rate prostate brachytherapy treatment planning system (TPS). We evaluated the dosimetric and planning accuracy of this new TPS compared to the universally used VariSeed TPS. For dosimetric evaluation of the MIM Symphony version 5.4 TPS, we compared dose calculations from the MIM Symphony TPS with the formalism recommended by the American Associatio...

متن کامل

A novel perineal shield for low-dose-rate prostate brachytherapy

PURPOSE To study the impact on radiation exposure to staff through the use of an original perineal shield during low-dose-rate prostate brachytherapy. MATERIAL AND METHODS We designed a 1 mm thick stainless steel shield that duplicates and is able to slide directly over a standard commercialized prostate brachytherapy grid. We then analyzed the post-procedure exposure in 15 consecutive patien...

متن کامل

Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer – between options

PURPOSE Permanent low-dose-rate (LDR-BT) and temporary high-dose-rate (HDR-BT) brachytherapy are competitive techniques for clinically localized prostate radiotherapy. Although a randomized trial will likely never to be conducted comparing these two forms of brachytherapy, a comparative analysis proves useful in understanding some of their intrinsic differences, several of which could be exploi...

متن کامل

High dose rate brachytherapy for prostate cancer.

High dose rate (HDR) afterloading brachytherapy in the management of localised prostate cancer has practical, physical and biological advantages over low dose rate seed brachytherapy. There are no free live sources used, no risk of source loss and since the implant is a temporary procedure following discharge no issues with regard to radioprotection use of existing facilities. Adequate coverage...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Brachytherapy

سال: 2021

ISSN: ['1873-1449', '1538-4721']

DOI: https://doi.org/10.1016/j.brachy.2020.10.006