A comparison of the implant stability among various implant systems: clinical study
نویسندگان
چکیده
منابع مشابه
A comparison of the implant stability among various implant systems: clinical study
PURPOSE To determine the change in stability of single-stage, three different design of implant systems in humans utilizing resonance frequency analysis for early healing period (24 weeks), without loading. MATERIAL AND METHODS Twenty-five patients were included into this study. A total of 45 implants, three different design of implant systems (group A,C,R) were placed in the posterior maxill...
متن کاملImplant stability comparison of immediate and delayed maxillary implant placement by use of resonance frequency analysis--a clinical study.
The purpose of this study was to objectively evaluate the stability of dental implants by use of resonance frequency analysis (RFA). In this study, 60 Nobel Replace Tapered Groovy implants were placed in the premolar region of the maxilla in 60 patients. Thirty implants were placed immediately after tooth extraction and 30 implants were placed in healed bone sites. Implant stability quotient (I...
متن کاملThe accuracy of various torque wrenches used in dental implant systems
Introduction: The purpose of this study was to compare the accuracy of the torque wrenches used in different dental implant systems. Methods: We evaluated 42 torque wrenches used in different dental clinics in Mashhad, Iran, using a digital torque meter (Mark 10). High (25, 30 and 35 N·cm) and low (15 N·cm) levels of torque were examined. Ten tests were performed on each wrench, and the mean va...
متن کاملInfluence of bone density on implant stability parameters and implant success: a retrospective clinical study
BACKGROUND The aim of the present clinical study was to determine the local bone density in dental implant recipient sites using computerized tomography (CT) and to investigate the influence of local bone density on implant stability parameters and implant success. METHODS A total of 300 implants were placed in 111 patients between 2003 and 2005. The bone density in each implant recipient sit...
متن کاملUpdated secondary implant stability data of two dental implant systems. A retrospective cohort study
BACKGROUND At present, updated secondary implant stability data generated by actual versions of resonance frequency analysis (RFA) and mobility measurement (MM) electronic devices of 2 different implant systems with actual manufactured surfaces seem to lack and/or are incomplete. MATERIAL AND METHODS Secondary implant stability data based on both RFA and MM measurements were collected and ana...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Advanced Prosthodontics
سال: 2009
ISSN: 2005-7806
DOI: 10.4047/jap.2009.1.1.31