A Comparison of Double-End Partial Discharge Localization Algorithms in Power Cables
نویسندگان
چکیده
The double-end partial discharge (PD) measurement method is the most common for measuring and localizing PD sources in power cables. sensitivity of sensor, processing speed data acquisition unit, localization algorithm are three main keys to ensuring accuracy source on A new multi-end known as segmented correlation trimmed mean (SCTM) has recently demonstrated excellent algorithm, however, only applicable methods. In this paper, mathematical equation SCTM customized match method. MATLAB simulation was conducted assess performance maximum peak detection (MPD) (SC), were compared algorithms. SC algorithms have shown that identifying bond between two cues instead signal MPD significantly increases accuracy. results show outperforms terms
منابع مشابه
Partial Discharge Simulation and Analysis Based on Experiment in Underground Distribution Power Cables
This paper describes the simulation and experiment for partial discharge (PD) pulse propagation in 22.9kV CNCV power cables. To investigate the propagation characteristics of PD, experiments are carried out by injecting the PD pulse in 100m-long 60 mm 2 CNCV cable in the laboratory. The characteristics of PD are also simulated using EMTP to investigate and analyze PD in the same cable. By compa...
متن کاملThe Application of Partial Discharge Detection for the condition assessment of XLPE Power Cables
Partial discharge (PD) detection is an important means in the condition-based maintenance of high voltage apparatus including crosslinked polyethylene (XLPE) power cables. In this contribution, we introduce the recent work in Shanghai municipal electric power company on the condition-based maintenance of XLPE power cables. As to how to carry out the PD detection in different circumstances, thre...
متن کاملAdvanced technique for partial discharge detection and analysis in power cables
Polymeric cables are the most common choice for transmission and distribution in populated areas, as well as for the connection of components (transformers, GIS, etc.) in new power stations, replacing paper-oil cables. Indeed, they do possess superior characteristics with respect to oil-filled cables. As an example, they do require lower maintenance, they are lighter (easier to deploy) and, in ...
متن کاملOn-site Portable Partial Discharge Detection Applied to Power Cables Using HFCT and UHF methods
Partial discharge (PD) events happen inside the power cables and cable terminations with the insulation degradation. The PD detection can effectively supply the information of cable status. According to the electrical and electromagnetic emission of PD activities, high-frequency transformer (HFCT) and ultrahigh-frequency (UHF) methods are employed to detect the PD signals. Besides, a portable P...
متن کاملReturn to Session PARTIAL DISCHARGE DETECTION IN POWER CABLES: PRACTICAL LIMITS AS A FUNCTION OF CABLE LENGTH
Power cables behave as transmission lines as regards partial discharge (PD) pulse propagation. Attenuation and dispersion phenomena have, therefore, great influence on the detectability of PD pulses, particularly when long cable routes and detection from terminals are considered. This paper presents an approximate model to infer PD pulse waveform as a function of the distance travelled along th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2023
ISSN: ['1996-1073']
DOI: https://doi.org/10.3390/en16041817