A comparison of 2 second generation drug eluting stents (Zotarolimus versus Everolimus), in elective PCI patients

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of zotarolimus-eluting and everolimus-eluting coronary stents.

BACKGROUND New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed by the Food and Drug Administration. METHODS In this multicenter, noninferiority trial with mi...

متن کامل

A randomized controlled trial in second-generation zotarolimus-eluting Resolute stents versus everolimus-eluting Xience V stents in real-world patients: the TWENTE trial.

OBJECTIVES The aim of this study was to compare the safety and efficacy of Resolute zotarolimus-eluting stents (ZES) (Medtronic Cardiovascular, Santa Rosa, California) with Xience V everolimus-eluting stents (EES) (Abbott Vascular Devices, Santa Clara, California) at 1-year follow-up. BACKGROUND Only 1 randomized trial previously compared these stents. METHODS This investigator-initiated, p...

متن کامل

Everolimus-eluting Xience v/Promus versus zotarolimus-eluting resolute stents in patients with diabetes mellitus.

OBJECTIVES This study sought to compare everolimus-eluting stents (EES) versus Resolute zotarolimus-eluting stents (ZES) in terms of patient- or stent-related clinical outcomes in an "all-comer" group of patients with diabetes mellitus (DM) who underwent percutaneous coronary intervention. BACKGROUND DM significantly increases the risk of adverse events after percutaneous coronary interventio...

متن کامل

Second Generation Drug-Eluting Stents: A Review of the Everolimus-Eluting Platform

Everolimus-eluting stents (EES) represent the next generation of drug-eluting stents (DES). Important design modifications include thin strut stent backbones, less inflammatory and more biocompatible polymers, and lower drug dosing. The cobalt chromium EES fluoropolymer XIENCE V stent has been the most extensively studied of such stents. In animal models, this stent demonstrated minimal vessel ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: European Heart Journal

سال: 2013

ISSN: 0195-668X,1522-9645

DOI: 10.1093/eurheartj/eht309.p3028