A comparison between uniform and galvanic corrosion rate in carbonation induced corrosion of reinforced concrete
نویسندگان
چکیده
Carbonation-induced corrosion is usually considered in uniform or generalized corrosion. This true for small laboratory samples but not necessary the case real reinforced concrete structures built with multilayers reinforcement. Multi-layers reinforcement could lead to a galvanic between first de-passivated layer closed surface and deeper layers still passivated. The present paper compares density made two different type of cements. CEM III cement despite their higher susceptibility carbonation show significant lower density, which would increase service life RC structures, exposed carbonation.
منابع مشابه
Comparison of uniform and non-uniform corrosion induced damage in reinforced concrete based on a Gaussian description of the corrosion layer
A Gaussian function is proposed to describe the non-uniform spatial distribution of corrosion products as measured from chloride-exposed reinforced concrete specimens using backscattered electron imaging and image analysis. The model provides a good fit to the observed data and limited data sets reported in the literature. Subsequently it is used as an input into a finite element analysis to pr...
متن کاملCorrosion Monitoring of Reinforced Concrete Structures - A Review
Reinforced concrete structures have the potential to be very durable and capable of withstanding a variety of adverse environmental conditions. However, failures in the structures do still occur as a result of premature reinforcement corrosion. The maintenance and repair of bridges and buildings for their safety requires effective inspection and monitoring techniques for assessing the reinforce...
متن کاملCorrosion-Induced Concrete Cracking Model Considering Corrosion-Filled Paste
A TCP–TCL model is established to describe the relationship between the thickness of the corrosion-filled paste (CP) and that of the corrosion layer (CL). This model can describe the phenomenon that the corrosion filling in the concrete pores and accumulating at the steel/concrete interface occur synchronously. Based on the TCP–TCL model, a corrosion-induced concrete cracking model, which can q...
متن کاملMonitoring Corrosion of Steel Bars in Reinforced Concrete Structures
Corrosion of steel bars embedded in reinforced concrete (RC) structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to pres...
متن کاملA Galvanic Sensor for Monitoring the Corrosion Condition of the Concrete Reinforcing Steel: Relationship Between the Galvanic and the Corrosion Currents
This work reports a study carried out on the design and performance of galvanic and polarization resistance sensors to be embedded in concrete systems for permanent monitoring of the corrosion condition of reinforcing steel, aiming to establish a correlation between the galvanic currents, I(gal), and the corrosion currents, I(corr), estimated from the polarization resistance, R(p). Sensors have...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATEC web of conferences
سال: 2022
ISSN: ['2261-236X', '2274-7214']
DOI: https://doi.org/10.1051/matecconf/202236402025