A Colorimetric Method for Quantifying Cis and Trans Alkenes Using an Indicator Displacement Assay

نویسندگان

چکیده

A colorimetric indicator displacement assay (IDA) amenable to high-throughput experimentation was developed determine the percentage of cis and trans alkenes. Using 96-well plates two steps are performed: a reaction plate for dihydroxylation alkenes followed by an IDA screening consisting boronic acid. The generates either erythro or threo vicinal diols from alkenes, depending upon their syn- anti-addition mechanisms. Threo preferentially associate with acid due creation more stable boronate esters, thus displacing greater extent. generality protocol demonstrated using seven sets Blind mixtures were made, resulting in average error ±2 % implementing E2 Wittig reactions gave errors ±3 %. Furthermore, we variants which color may be tuned optimize response human eye.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reaction-based Indicator displacement Assay (RIA) for the selective colorimetric and fluorometric detection of peroxynitrite.

Using the self-assembly of aromatic boronic acids with Alizarin Red S (ARS), we developed a new chemosensor for the selective detection of peroxynitrite. Phenylboronic acid (PBA), benzoboroxole (BBA) and 2-(N,N-dimethylaminomethyl)phenylboronic acid (NBA) were employed to bind with ARS to form the complex probes. In particular, the ARS-NBA system with a high binding affinity can preferably reac...

متن کامل

Mechanism of cis/trans equilibration of alkenes via iodine catalysis.

Iodine is commonly used to speed the equilibration of Wittig cis/trans alkene products. This study uses computational chemistry to study the catalyzed isomerization mechanism in detail for seven different examples of 1,2-disubstituted alkenes. We find that the iodo intermediates of the conventional three-step reaction path are weakly stable, bound by less than 7 kJ mol(-1) in five cases and non...

متن کامل

Using ratiometric indicator-displacement assays in semi-quantitative colorimetric determination of chloride, bromide, and iodide anions.

A ratiometric indicator-displacement assay (RIDA) array has been developed for the semi-quantitative colorimetric determination of chloride, bromide, and iodide anions. Determinations of these halide anions follow the displacement reaction using the chelate compound of (2-(3,5-dibromo-2-pyridylazo)-5-(diethylamino)phenol) (3,5-Br2-PADAP) and heavy metal salts as colorimetric reagent. Different ...

متن کامل

Carbohydrate sensing with a metal-based indicator displacement assay.

A Pd-based indicator displacement assay for the fluorimetric sensing of carbohydrates has been developed. The assay allows the detection of saccharides in the low millimolar concentration range in water at neutral pH.

متن کامل

Indicator displacement assay for cholesterol electrochemical sensing using a calix[6]arene functionalized graphene-modified electrode.

A novel electrochemical method has been developed towards cholesterol detection based on competitive host-guest interaction by selecting methylene blue (MB) and calix[6]arene functionalized graphene (CX6-Gra) as the "reporter pair". In the presence of cholesterol, the MB molecules are displaced by cholesterol in the CX6-Gra.MB complex, leading to a "switch off" electrochemical response. A linea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Angewandte Chemie

سال: 2021

ISSN: ['1521-3773', '1433-7851', '0570-0833']

DOI: https://doi.org/10.1002/ange.202101004