A Coefficient to Characterize Mixing in Solar Water Storage Tanks
نویسندگان
چکیده
منابع مشابه
Opportunistic pathogens relative to physicochemical factors in water storage tanks.
Household water in Oman, as well as in other countries in the region, is stored in tanks placed on house roofs that can be subjected to physicochemical factors which can promote microbial growth, including pathogens and opportunistic pathogens which pose health risks. Water samples were collected from 30 houses in a heavily populated suburb of Muscat. The tanks used were either glass reinforced...
متن کاملIntroduction of Air Cushion to Reduce Seismic Demand in Cylindrical Water Storage Tanks
Water storage tanks not designed explicitly for seismic loading could require retrofit. One of the common ways of retrofit include some structural change in the lateral load resisting system that could be expensive and requires the tank to be out of service for relatively long time. This paper introduces a novel method to reduce seismic demand on tank’s wall without structural intervention. Thi...
متن کاملIntroducing Padded Wall to Reduce Sloshing Induced Wall Pressure in Water Storage Tanks
Sloshing due to ground motion develops large pressure on the walls of water retaining tanks. This paper evaluates the efficacy of padded walls on the reduction of sloshing effects in rectangular water storage tanks subjected to ground motion. An analytical solution based on velocity potential function is provided to obtain the response of rigid and padded wall tanks in terms of the wave elevat...
متن کاملUsing radium isotopes to characterize water ages and coastal mixing rates: A sensitivity analysis
Numerous studies have used naturally occurring Ra isotopes (223Ra, 224Ra, 226Ra, and 228Ra, with half-lives of 11.4 d, 3.7 d, 1600 y, and 5.8 y, respectively) to quantify water mass ages, coastal ocean mixing rates, and submarine groundwater discharge (SGD). Using Monte Carlo models, this study investigated how uncertainties in Ra isotope activities and the derived activity ratios (AR) arising ...
متن کاملRunaway Prevention in Cumene Hydroperoxide Storage Tanks
In this work thermal runaway of cumene hydroperoxide (CHP) in a storage tank with constant jacket temperature is considered. The divergence method developed by Strozzi and Zaldivar (1994) based on the concept of parametric sensitivity and a runaway criterion focused on a set of critical parameters identified by Velo et al. (1996) have been applied to our system. The results obtained from the co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Solar Energy Engineering
سال: 1994
ISSN: 0199-6231,1528-8986
DOI: 10.1115/1.2930504