A closed subspace of $\mathcal{D}(\Omega)$ which is not an $\mathrm{LF}$-space
نویسندگان
چکیده
منابع مشابه
An ACCL which is not a CRCL
It is fairly easy to show that every regular set is an almost-confluent congruential language (ACCL), and it is known [3] that every regular set is a Church-Rosser congruential language (CRCL). Whether there exists an ACCL, which is not a CRCL, seems to remain an open question. In this note we present one such ACCL.
متن کاملAn Example of a Differentiability Space Which Is Pi-unrectifiable
We construct a (Lipschitz) differentiability space which has at generic points a disconnected tangent and thus does not contain positive measure subsets isometric to positive measure subsets of spaces admitting a Poincaré inequality. We also prove that l-valued Lipschitz maps are differentiable a.e., but there are also Lipschitz maps taking values in some other Banach spaces having the Radon-Ni...
متن کاملClosed-loop subspace identification using the parity space
It is known that many subspace algorithms give biased estimates for closed-loop data due to the existence of feedback. In this paper we present a new subspace identification method using the parity space employed in fault detection in the past. The basic algorithm, known as subspace identification method via principal component analysis (SIMPCA), gives consistent estimation of the deterministic...
متن کاملNiemytzki Plane - an Example of Tychonoff Space Which Is Not T4
We continue Mizar formalization of General Topology according to the book [20] by Engelking. Niemytzki plane is defined as halfplane y ≥ 0 with topology introduced by a neighborhood system. Niemytzki plane is not T4. Next, the definition of Tychonoff space is given. The characterization of Tychonoff space by prebasis and the fact that Tychonoff spaces are between T3 and T4 is proved. The final ...
متن کاملMRS Shimming: An Important Point Which Should not be Ignored
Introduction: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. There are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a proc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Proceedings of the American Mathematical Society
سال: 1970
ISSN: 0002-9939
DOI: 10.1090/s0002-9939-1970-0257689-0