A clamping type DC circuit breaker with short fault isolation time and low energy dissipation

نویسندگان

چکیده

The development of DC grids faces challenges from fault protection. conventional circuit breaker (DCCB) employs metal-oxide varistor (MOV) to isolate the faulted line, in which isolation process is coupled with energy dissipation process. In this study, a clamping type DCCB (CTCB) uses internal capacitors clamp converter voltage proposed. Thanks proposed configuration, and are decoupled, resulting fast low compared DCCB. working principle CTCB presented verified grid simulation model. A comparison made traditional time can be reduced by 34.5 %. dissipated 17.4 power 76.2 1

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Circuit Topology for Open Circuit and Short Circuit Fault Tolerant Dc - Dc Converter

This paper describes a new design for a fault tolerant Hbridge dc-dc converter. Open circuit and short circuit fault tolerance is achieved using multilevel converter topology in combination with pulse width modulation control strategy allowing a large set of converter switching states to produce bidirectional power flows at any required output voltage. If two switches fail at particular instant...

متن کامل

A Modernistic Approach to Design Fault Tolerant Circuit Using LP-LFSR with Low Power Dissipation

The aim of testing of VLSI circuits is high-quality screening of the circuits by targeting performance related faults. A low hardware overhead test pattern generator (TPG) for scan based BIST that can detect the any faults in the circuit under test and analyze their response .It is a new fault coverage test pattern generator using a liner feedback shift register (LFSR) called FC-LFSR can perfor...

متن کامل

Investigating Impacts of Sustainable Repair Time and Circuit Breaker Model on Meshed Distribution Networks Reliability Assessment

Generally, the failure rate and the repair time of system components are constant parameters in reliability assessment of electric distribution systems. A failure of component is resulted from failing in the operation or overloading. In addition, there exist cases where, the repair times of components are small and tolerable from customer point of view. Thus, tolerable repair times may be overl...

متن کامل

Of a High Current Hvdc Circuit Breaker with Fast Fault Clearing Capability

Recent yea rs have seen r a p i d growth i n d i r e c t c u r r e n t t ransmiss ion. Th is growth increases the need and scope o f a p p l i c a t i o n f o r a h i g h vo l tage d i r e c t c u r r e n t c i r c u i t breaker . S i g n i f i c a n t improvements have been made i n a p r e v i o u s l y developed 500 kV, 2000A HVdc c i r c u i t breaker . These improvements have increased t h...

متن کامل

Energy dissipation in an adaptive molecular circuit

The ability to monitor nutrient and other environmental conditions with high sensitivity is crucial for cell growth and survival. Sensory adaptation allows a cell to recover its sensitivity after a transient response to a shift in the strength of extracellular stimulus. The working principles of adaptation have been established previously based on rate equations which do not consider fluctuatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: CSEE Journal of Power and Energy Systems

سال: 2021

ISSN: ['2096-0042']