A case report of stomach perforation during automatic mechanical chest compression following pulseless electrical activity due to cibenzoline intoxication
نویسندگان
چکیده
منابع مشابه
Continuous mechanical chest compression during in-hospital cardiopulmonary resuscitation of patients with pulseless electrical activity.
UNLABELLED Survival after in-hospital pulseless electrical activity (PEA) cardiac arrest is poor and has not changed during the last 10 years. Effective chest compressions may improve survival after PEA. We investigated whether a mechanical device (LUCAS™-CPR) can ensure chest compressions during cardiac arrest according to guidelines and without interruption during transport, diagnostic proced...
متن کاملPulseless electrical activity during electroconvulsive therapy: a case report
BACKGROUND Arrhythmias resulting in cardiac arrest during electroconvulsive therapy have been reported. Most reported cases of cardiac arrest had asystole as the initial rhythm. Pulseless electrical activity as an initial rhythm of cardiac arrest during electroconvulsive therapy has never been reported. Also, thromboembolism after inflation of pneumatic tourniquet during lower limb surgery has ...
متن کاملEsophageal Perforation Due to Nasogastric Tube Insertion: A Case Report
Introduction: A Nasogastric (NG) tube insertion is a common technique in all neonatal intensive care units (NICUs). In some cases, NG insertion in infants with friable esophageal tissues may lead to some adverse side-effects, although such problems are not commonly seen. Esophageal perforation is a rare but known complication associated with this procedure. Methods: An infant (first child), we...
متن کاملPulseless electrical activity arrest due to air embolism during endoscopic retrograde cholangiopancreatography: a case report and review of the literature
While most gastroenterologists are aware of the more common complications of endoscopy such as bleeding, infection and perforation, air embolism remains an under-recognised and difficult to diagnose problem due to its varying modes of presentation. This is the case of a 55-year-old man with right upper quadrant pain and imaging notable for cholecystitis and choledocholithiasis, who underwent en...
متن کاملAutomated continuous chest compression for in-hospital cardiopulmonary resuscitation of patients with pulseless electrical activity: a report of five cases.
Of patients with in-hospital cardiac arrest, those with pulseless electrical activity (PEA) have the worst outcome. Especially in these patients effective chest compressions according to the guidelines may be the key strategy to improve survival. Recently, a novel automatic mechanical chest compression device (LUCAS-CPR) has been shown to ensure effective continuous compressions without interru...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acute Medicine & Surgery
سال: 2021
ISSN: 2052-8817,2052-8817