Micropulse versus continuous wave transscleral diode cyclophotocoagulation in refractory glaucoma: a randomized exploratory study.

BACKGROUND The aim of this study was to compare the efficacy and safety of micropulse and continuous wave diode transscleral cyclophotocoagulation in refractory glaucoma. DESIGN Randomized, comparative, exploratory study in a tertiary hospital setting. PARTICIPANTS Patients with refractory, end-stage glaucoma. METHODS Forty-eight patients were randomized to either treatment. The intraocul...

متن کامل

Micropulse transscleral diode laser cyclophotocoagulation in the treatment of refractory glaucoma.

BACKGROUND Transscleral diode laser cyclophotocoagulation (TSCPC) is an established method of treatment for refractory glaucoma, but is associated with significant complications. This study evaluates the efficacy and safety of a new form of TSCPC using micropulse diode laser and trans-pars plana treatment with a novel contact probe. METHODS Prospective interventional case series of 40 eyes of...

متن کامل

Micropulse P3 Glaucoma Device Revolutionizes Cyclophotocoagulation

The newly patented MicroPulse P3 (MP3) device (Iridex) provides the surgeon a very safe and efficacious solution to treating glaucoma utilizing Iridex’s proprietary MicroPulse technology. While sharing similarities to G-Probe (Iridex), the primary advantage is the MP3 provides a kinder, gentler approach with identical efficacy yet improved safety profile.1 I have had the opportunity to be invol...

متن کامل

Treatment of malignant glaucoma with contact transscleral cyclophotocoagulation.

Fivecasesofpseudophakicmalignant glaucoma were successfully treated with a single session of contact transscleralcyclophotocoagulation(CTCP) withdiodelaser(twenty4-Jspotsover 360°,1.5mmposterior to the limbus) after failureofNd:YAGlaserhyaloidotomy and vitreolysis. All patients except for case 2 had a preoperative diagnosis of chronic angle-closure glaucoma. At the end of the followup, all the ...

متن کامل

MicroPulse Laser Trabeculoplasty for the Treatment of Open-Angle Glaucoma

The aim of the study was to investigate the safety and efficacy of using MLT in the treatment of open-angle glaucoma (OAG).This prospective cohort included subjects ≥18 years of age with OAG, defined as the open angle on gonioscopy with glaucomatous optic neuropathy evident from optical coherence tomography. Subjects with IOP < 21 mm Hg were classified as normal tension glaucoma and those with ...