A case of falsely elevated D-dimer result

نویسندگان

چکیده

Abstract Objectives Heterophile antibodies can cause interferences in immunometric assays. While many tests are shown to be affected by interference from heterophilic antibodies, the D-dimer test has rarely been reported affected. With this case, we report an elevated measurement which was not compatible with clinical presentation. Case presentation A 41-year-old patient who admitted hospital heart palpitations had a elevation irrelevant his condition. measurements were repeated new samples directly and after being treated blocking tube two different reagent lots of latex-based automated immunoturbidimetric assay immunoturbidometric assay. values normalized (0–0.5 mg/L) when used lot on same instrument or measured method chemistry analyzer. After treatment HBT, all revealed results within reference ranges. Conclusions The presence heterophile sample should considered value that is encountered. Apart patient’s HA’s causing false results, sporadic susceptibility reagents also kept mind as possibility.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Falsely elevated troponin levels.

To diagnose a myocardial infarction, an increase and/or fall in troponin values by at least one value > the 99th percentile in a healthy reference population is required, combined with other ischaemic signs or symptoms (1). Troponin T and troponin I are considered equal in diagnostics of myocardial infarction. There is only one manufacturer of tests for troponin T and thus only one reference ra...

متن کامل

Weil's disease with elevated plasma D-dimer.

We report a case of Weil's disease manifesting elevation of plasma D-dimer in the acute phase. Later, in the convalescent phase after treatment, the plasma levels of D-dimer returned to normal. Plasma D-dimer can be used as a marker of fibrin formation and degradation. Based on our observations, we conjecture that fibrin formation and fibrinolysis may occur in the acute phase of Weil's disease.

متن کامل

Elevated level of D-dimer increases the risk of stroke

The aim of this study was to systematically evaluate the association between D-dimer level and the risk of stroke through performing a meta-analysis. PubMed, Web of Science, EMBASE and Cochrane Library were searched for potentially eligible literature. Prospective observational studies or case-control studies were included. The study characteristics and relevant data were extracted. Hazard rati...

متن کامل

Falsely elevated prothrombin international normalized ratio values.

International normalized ratio (INR) monitoring is essential during oral anticoagulation therapy to minimize bleeding complications and thrombotic events. Laboratory technicians cannot differentiate falsely elevated INR results due to problems in drawing blood from truly elevated INR values, but the extent of this phenomenon is unclear. We determined the proportion of patients with INR values o...

متن کامل

a comparison of linguistic and pragmatic knowledge: a case of iranian learners of english

در این تحقیق دانش زبانشناسی و کاربردشناسی زبان آموزان ایرانی در سطح بالای متوسط مقایسه شد. 50 دانش آموز با سابقه آموزشی مشابه از شش آموزشگاه زبان مختلف در دو آزمون دانش زبانشناسی و آزمون دانش گفتار شناسی زبان انگلیسی شرکت کردند که سوالات هر دو تست توسط محقق تهیه شده بود. همچنین در این تحقیق کارایی کتابهای آموزشی زبان در فراهم آوردن درون داد کافی برای زبان آموزان ایرانی به عنوان هدف جانبی تحقیق ...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Türk biyokimya dergisi

سال: 2022

ISSN: ['1303-829X']

DOI: https://doi.org/10.1515/tjb-2021-0262