A calibration method for patient specific IMRT QA using a single therapy verification film
نویسندگان
چکیده
منابع مشابه
Reproducibility in patient‐specific IMRT QA
The purpose of this study was to determine the reproducibility of patient-specific, intensity-modulated radiation therapy (IMRT) quality assurance (QA) results in a clinical setting. Six clinical patient plans were delivered to a variety of devices and analyses, including 1) radiographic film; 2) ion chamber; 3) 2D diode array delivered and analyzed in three different configurations (AP deliver...
متن کاملCharacterization of cylindrical ionization chambers for patient specific IMRT QA
Proven conventional dosimetry techniques do not provide accuracy and precision in the measurement of inverse planned intensity modulated radiation therapy (IMRT) fields. Dynamic and step-and-shoot multileaf collimation (DMLC/SMLC) challenge current ionization chamber dosimetry practices. Ionization chamber performance in these fields is evaluated for three cylindrical chambers of varying volume...
متن کاملRapid radiographic film calibration for IMRT verification using automated MLC fields.
A method for measuring a film sensitometric curve using a single sheet of film exposed with a two field step-and-shoot MLC treatment was developed and tested with Kodak XV2 and EDR2 films. With this technique a film sensitometric curve can be completed in only 10 minutes, making it practical to generate new film calibrations daily. This method is applicable to film calibrations for all purposes...
متن کاملPoint/Counterpoint. Patient-specific QA for IMRT should be performed using software rather than hardware methods.
Suggestions for topics suitable for these Point/Counterpoint debates should be addressed to Colin G. Orton, Professor Emeritus, Wayne State University, Detroit: [email protected]. Persons participating in Point/Counterpoint discussions are selected for their knowledge and communicative skill. Their positions for or against a proposition may or may not reflect their personal opinions or the pos...
متن کاملConfidence limits for patient‐specific IMRT dose QA: a multi‐institutional study in Korea
This study aims to investigate tolerance levels for patient-specific IMRT dose QA (DQA) using the confidence limits (CL) determined by a multi-institutional study. Eleven institutions participated in the multi-institutional study in Korea. A total of 155 DQA measurements, consisting of point-dose differences (high- and low-dose regions) and gamma passing rates (composite and per-field) for IMRT...