A 40‐Centimeter Trochoidal Type Mass Spectrometer: Trochotron
نویسندگان
چکیده
منابع مشابه
Electric Ion Dispersion as a New Type of Mass Spectrometer
At the 2014 Fields-MPrime Industrial Problem Solving Workshop, PerkinElmer presented a design problem for mass spectrometry. Traditionally mass spectrometry is done via three methods: using magnetic fields to deflect charged particles whereby different masses bend differently; using a time-of-flight procedure where particles of different mass arrive at different times at a target; and using an ...
متن کاملDesign, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کاملThe Orbitrap: a new mass spectrometer.
Research areas such as proteomics and metabolomics are driving the demand for mass spectrometers that have high performance but modest power requirements, size, and cost. This paper describes such an instrument, the Orbitrap, based on a new type of mass analyzer invented by Makarov. The Orbitrap operates by radially trapping ions about a central spindle electrode. An outer barrel-like electrode...
متن کاملA Benchtop Inductively Coupled Plasma Mass Spectrometer
Inductively coupled plasma mass spectrometry (ICP-MS) is an analytical technique that performs elemental analysis with excellent sensitivity and high sample throughput. The ICP-MS instrument employs a plasma (ICP) as the ionization source and a mass spectrometer (MS) analyzer to detect the ions produced. It can simultaneously measure most elements in the periodic table and determine analyte con...
متن کاملA quadrupole mass spectrometer for resolution of low mass isotopes.
The qualitative and quantitative identification of low mass isotopes in the mass range 1-6 u poses certain difficulties when attempting to achieve the required resolution with an instrument suitable for deployment within a process environment. Certain adjacent species present in the process sample (HT and D(2)) require a resolution greater than 930 to achieve an accurate measurement. We demonst...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 1947
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.1740844