974 Non-invasive transabdominal assessment of In-Utero fetal oxygen saturation in a hypoxic lamb model

نویسندگان

چکیده

Fetal heart rate monitoring is a poor predictor of fetal hypoxia due to its high false-positive rate. Utilizing novel transabdominal pulse oximeter (TFO), this study aimed demonstrate the feasibility non-invasive and direct assessment arterial blood oxygen saturation in-utero (SaO2) in hypoxic lamb model. was induced 3 gravid term ewes (137.3±3.2 days gestation) by placing an inflatable balloon catheter infrarenal aorta via common femoral artery (Fig 1). A carotid line placed for continuous hemodynamic gases (ABG). The uterus closed around right forelimb, laparotomy closed, leaving limb exposed conventional oximetry. fetus’s depth from ewe’s skin determined, TFO device on abdomen. aortic inflated stepwise fashion decrease distal mean pressure (dMAP) 5mmHg increments. At each step, dMAP maintained 10 min, ABGs were recorded at 2.5, 5, 10-min marks. fully deflated after two consecutive measurements SaO2 <15%. fetus recovered 45 gradient repeated second round. level, average measured (SpO2) compared SaO2. SpO2 2A) found be highly correlative (R=0.64 p<0.0001) 2B). ex-utero clinical readings forelimb had weak correlation with (R=0.16 p<0.0003). depth, composed abdominal wall uterine thickness, 15.0±4.3mm (SD). can measure based despite intervening maternal anatomy. potentially improve accuracy detection. Future research will focus intrapartum validation models human pregnancies.View Large Image Figure ViewerDownload Hi-res image Download (PPT)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transabdominal near infrared oximetry of hypoxic stress in fetal sheep brain in utero.

The feasibility of transabdominal near-infrared (NIR) spectroscopy for detecting and quantifying fetal hypoxia in utero is demonstrated in a pregnant ewe model. A frequency domain NIR spectroscopy probe, consisting of two detectors and six sources operating at three wavelengths (675, 786, and 830 nm), was placed on the maternal abdomen directly above the fetal head. Fetal hypoxia was indirectly...

متن کامل

Fetal transabdominal pulse oximeter studies using a hypoxic sheep model.

OBJECTIVE This study investigates the validity of transabdominal pulse oximetry using a sheep fetal hypoxia model with fetal arterial hemoglobin saturation. METHODS Four pregnant ewes were anaesthetized and cannulated through the brachial artery to measure direct arterial blood saturation, SaO(2). Next, the transabdominal pulse oximeter was used to measure indirect measurement of the arterial...

متن کامل

Saturation oxygen pressure index for assessment of pulmonary disease in neonates on non-invasive ventilation.

This prospective observational study on 36 neonates aimed to estimate the correlation between the new Saturation Oxygen distending Pressure Index (SOPI) and Oxygenation index. SOPI had high correlation (r=0.94) with oxygenation index. SOPI of <2, 2, and 3.7 represented mild, moderate and severe pulmonary disease, respectively with high sensitivity and specificity.

متن کامل

features of short story in translated and non-translated literature: a polysystemic perspective

ترجمه متون ادبی در دنیای امروز از اهمیت ویژه ای برخوردار است. فرهنگ های مختلف با استفاده از متون ادبی ملل و فرهنگ های دیگر سعی در غنی کردن فرهنگ و ادبیات کشور خود دارند. کشور ما نیز از این قاعده مستثنی نیست. در ایران، ترجمه متون ادبی اروپائی که با دوران مشروطه ایرانی آغاز می شود موجب تغییرات اساسی در فرهنگ، شیوه زندگی و تفکر ایرانیان شده است. در این دوران نه تنها در امورات سیاسی و فکری کشور تغی...

15 صفحه اول

assessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks

testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: American Journal of Obstetrics and Gynecology

سال: 2021

ISSN: ['1097-6868', '0002-9378', '1085-8709']

DOI: https://doi.org/10.1016/j.ajog.2020.12.999