919 Assessment of LV regional dyssynchrony: comparison between Real-time 3D echocardiography and Tissue Doppler analysis

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dyssynchrony Assessment with Tissue Doppler Imaging and Regional Volumetric Analysis by 3D Echocardiography Do Not Predict Long-Term Response to Cardiac Resynchronization Therapy

Background. Currently there are no reliable predictors of response to cardiac resynchronization therapy (CRT) before implantation. We compared pre-CRT left ventricular (LV) dyssynchrony by tissue Doppler imaging (TDI) and regional volumetric analysis by 3-dimensional transthoracic echocardiography (3DTTE) in predicting response to CRT. Methods. Thirty-eight patients (79% nonischemic cardiomyopa...

متن کامل

Assessment of left ventricular dyssynchrony and cardiac function in patients with different pacing modes using real-time three-dimensional echocardiography: Comparison with tissue Doppler imaging

The aim of this study was to evaluate the left ventricular mechanical dyssynchrony (LVMD) and left ventricular dysfunction of patients in AAI, DDD and VVI pacing modes using real-time three-dimensional echocardiography (RT3DE) and tissue Doppler imaging (TDI). The results from the RT3DE and TDI were subsequently compared. Twenty patients with sick sinus syndrome (SSS) who had undergone the impl...

متن کامل

Comparison between M-Mode and Doppler echocardiography in diagnosis

Introduction: Patent ductus arteriosus (PDA) is the persistence of a normal fetal structure between left pulmonary artery and descending aorta. Persistence of this fetal structure beyond 10 days of life is considered abnormal. In this study we compared M-Mode and Doppler echocardiography in diagnosis of PDA in children at Aliasghar Hospital in Zahedan and Children hospital in Bandar Abbas for...

متن کامل

Assessment of Atrial Septal Defect Role of Real-Time 3D Color Doppler Echocardiography for Interventional Catheterization

Background: Atrial septal defect (ASD) is easily thought to be a round hole in the atrial septum from the image of two-dimensional (2D) echocardiography. Even surgeons can not get the true morphology of an atrial septal defect because they only see the defect when the heart is already in a collapsed, non-beating condition. Pediatric interventional cardiologists, on the contrary, need to know th...

متن کامل

3D Echocardiography of the LV and RV

The evaluation of the global and regional left ventricular (LV) function is an essential part of a routine perioperative TEE-examination. To date, the assessment of the LV ejection fraction (EF) is mainly performed by “eye-balling”, which relies on the echocardiographer’s experience and ability to visually integrate spatial information. Further limitations of 2D-TEE assessment of the LV EF are ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: European Journal of Echocardiography

سال: 2006

ISSN: 1525-2167

DOI: 10.1016/s1525-2167(06)60574-x