7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Signal-to-noise ratio (SNR), RF field (B(1)), and RF power requirement for human head imaging were examined at 7T and 4T magnetic field strengths. The variation in B(1) magnitude was nearly twofold higher at 7T than at 4T ( approximately 42% compared to approximately 23%). The power required for a 90 degrees pulse in the center of the head at 7T was approximately twice that at 4T. The SNR avera...

متن کامل

Towards the Optimum 7T Head RF Coil

G. McKinnon, E. Boskamp GE Medical Systems, Waukesha, WI, United States Introduction Numerical simulations were used in an attempt to find the optimal configuration for a 7T head coil. The high-pass birdcage, the hybrid birdcage, and the TEM resonator were compared. The coil dimensions were kept as similar as possible. Performance was evaluated on the basis of normalized peak E field, SNR and B...

متن کامل

Automatically tuned and matched RF transceive head coil at 7T

Introduction The transmit efficiency and receive signal-to-noise ratio (SNR) of transceive RF coils depends on how well the resonance circuit is tuned to the Larmor frequency and matched to the 50 ohm coaxial cable. Patient size variability changes the load the coil couples with and adversely impacts both tuning and matching, and subsequently the power efficiency and SNR of the coil. The loadin...

متن کامل

Modelling and Simulation of Low-Head Hydro Turbine for Small Signal Stability Analysis in Power System

The hydro turbine dynamics have a considerable influence on the dynamic stability of power system. In the study of dynamic stability, the system is modeled by the linear differential equations (small  signal analysis). Small signal stability of power systems is needed in all conditions and only is dependent on the conditions of power system performance before commotion occurrence. This paper pr...

متن کامل

7T Current-Mode Class-D (CMCD) RF Power Amplifier

Introduction Today there is an intensive research effort in high-field MRI, mainly motivated by the higher SNR, and consequently higher spatial and temporal resolution attainable by higher magnetic fields. Counteracting these advantages are dielectric resonance effects when increasing sample size -as in the case of human imaging-, intravoxel dephasing due to increased susceptibility and increas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2001

ISSN: 0740-3194,1522-2594

DOI: 10.1002/mrm.1156