68Ga-fibroblast activation protein inhibitor PET/CT on gross tumour volume delineation for radiotherapy planning of oesophageal cancer

نویسندگان

چکیده

Background and purposeTo compare 68Ga-fibroblast activation protein inhibitor (FAPI) 18F-FDG PET/CT in imaging locally advanced oesophageal cancer, evaluate the potential usefulness of 68Ga-FAPI on gross target volume (GTV) delineation aimed at radiotherapy planning for cancer as compared with contrast-enhanced CT (CE-CT) PET/CT.Materials methodsTwenty-one patients newly diagnosed who underwent both scans were selected. GTVs primary tumours based CE-CT (GTVCT), PET/CT, plus delineated. Gross tumour lengths measured by endoscopy recorded.ResultsThe PET showed significantly higher radiotracer uptake than (median SUVmax 16.71 vs. 11.23; P = 0.002) tumours. SUV thresholds FAPI ×20%, 30%, 40%, FDG ×40% similar lesion that endoscopic examination (P > 0.05). GTVCT demonstrated largest (median: 48.80 mm3, range: 14.83–162.23 mm3) PET-based GTVs. For PET/CT-guided complementary contouring GTVCT, four (19%) increased ×20% two (9.5%) ×40%, only one patient was ×40%. Furthermore, GTV 40% no significant difference FAPI-PET meets organ risk standard.ConclusionThe methodology favourable tumour-to-background contrast might provide additional information help avoid geographic misses.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of the accuracy of automatic tumour functional volume delineation on radiotherapy treatment planning.

Over the past few years several automatic and semi-automatic PET segmentation methods for target volume definition in radiotherapy have been proposed. The objective of this study is to compare different methods in terms of dosimetry. For such a comparison, a gold standard is needed. For this purpose, realistic GATE-simulated PET images were used. Three lung cases and three H&N cases were design...

متن کامل

Multidisciplinary collaborative gross tumour volume definition for lung cancer radiotherapy: a prospective study

Variability in gross tumour volume (GTV) definition is a major source of systematic error in conformal radiotherapy. This prospective study assesses the role of multidisciplinary collaboration between oncologists and radiologists in defining lung cancer volumes. Twenty patients with non-small cell lung cancer due to receive three-dimensional conformal radiotherapy formed the study population. G...

متن کامل

The clinical application of 4D 18F-FDG PET/CT on gross tumor volume delineation for radiotherapy planning in esophageal squamous cell cancer

A combination of four-dimensional computed tomography with (18)F-fluorodeoxyglucose positron emission tomography (4D CT-FDG PET) was used to delineate gross tumor volume (GTV) in esophageal cancer (EC). Eighteen patients with EC were prospectively enrolled. Using 4D images taken during the respiratory cycle, the average CT image phase was fused with the average FDG PET phase in order to analyze...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...