52. Scatter subtraction by count ratio method in photopeak energy window
نویسندگان
چکیده
منابع مشابه
Attenuation correction of myocardial SPECT by scatter-photopeak window method in normal subjects.
OBJECTIVE Segmentation with scatter and photopeak window data using attenuation correction (SSPAC) method can provide a patient-specific non-uniform attenuation coefficient map only by using photopeak and scatter images without X-ray computed tomography (CT). The purpose of this study is to evaluate the performance of attenuation correction (AC) by the SSPAC method on normal myocardial perfusio...
متن کاملA modification of the dual energy window subtraction method for scatter compensation in pixelized scintillators for SPECT
Small field of view detectors based on Position Sensitive Photomultiplier Tubes (PSPMTs) have been widely used by many research groups in small-animal imaging and recently clinically in scintimammography. In most cases the PSPMT is coupled to pixelized scintillators since it has been shown that their use improves spatial resolution. The use of a single energy window for each crystal element is ...
متن کاملDetermination of the Energy Windows for the Triple Energy Window Scatter Correction Method in Gadolinium-159 Single Photon Emission Computed Tomography Using Monte Carlo Simulation
Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...
متن کاملThe Effect of FEW Scatter Correction Method in In-111 Imaging
Introduction: In nuclear medicine imaging, detection of the scattered photons along with the primary photons is one of the major problems that can lead to a decrease in ddiagnostic accuracy. Therefore, use of a suitable scatter correction method can help to improve of the image quality and increase of diagnostic accuracy. The aim of this study is evaluation of five energy wind...
متن کاملEfforts to Improve the Images from 67Ga Whole-Body Scintigraphy
The acquisition method for planar 67Ga imaging has hardly changed for 30 years. In this study, in order to improve image quality and diagnostic accuracy, we take steps to optimize the acquisition method, and to choose a scatter correction. First, we acquired individual images from the 93 keV, 185 keV, and 300 keV photopeak; then the images were added together and compared to the individual imag...