518 CYSTIC FIBROSIS SERUM FACTORS SEPARATED BY HIGH-PRESSURE VACUUM DIALYSIS AND COLUMN CHROMATOGRAPHY
نویسندگان
چکیده
منابع مشابه
Development of a Selective Post-column Detector for Phenols Separated by High-performance Liquid Chromatography
An on-line post-column reactor based on air-segmented continuous flow is described for the determination of phenols. The reaction used is the coupling of diazotized sulfanilic acid with phenols to form highly colored azo dyes. The effect of experimental parameters on the detector response was investigated by both univariate and simplex approaches in order to establish optimum reaction condition...
متن کاملSerum theophylline analysis by high-pressure liquid chromatography.
We have developed and evaluated a rapid, high-pressure liquid-chromatographic method for theophylline in serum. Only 0.2 ml of serum is required for each determination, and the sensitivity of this method is 0.5 mg/liter. This method, involving liquid extraction and silica adsorption chromatography, provides adequate selectivity, accuracy, and precision for routine or research applications. Litt...
متن کاملAssay of gentamicin in serum by high-pressure liquid chromatography.
A procedure is described that uses high-pressure liquid chromatography for assay of gentamicin in serum. The technique involves extraction of gentamicin from serum by using a CM-Sephadex column and analysis by reverse-phase, ion-pair chromatography. Continuous-flow, post-column derivatization with o-phthaladehyde is used to form fluorescent products for detection. The possible scope of this met...
متن کاملCharacterization of plasma lipoproteins separated and purified by agarose-column chromatography.
1. A simple method for isolation of individual human plasma lipoprotein classes is presented. In this technique, lipoproteins are removed from plasma at d1.225 by ultracentrifugation, after which they are separated and purified by agarose-column chromatography. 2. Three major classes are obtained after agarose-column chromatography. Separation between classes is excellent; more than 95% of the ...
متن کاملDirect determination of benzamides in serum by column-switching high-performance liquid chromatography.
A column-switching high-performance liquid chromatographic method with fluorescence detection was developed for the simultaneous determination of four benzamide-type anti-psychotic drugs: sulpiride, tiapride, sultopride and metoclopramide in human serum. In this method, a TSKgel Super-ODS column was used as an analytical column, and a TSKgel G 2000SW was prepared as a pretreatment column. Under...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Pediatric Research
سال: 1978
ISSN: 0031-3998,1530-0447