51. ^<201>Tl and ^<99m>Tc simultaneous acquision with 3windows 3data SPECT.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging

Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...

متن کامل

Brown adipose tissue: evaluation with 201Tl and 99mTc-sestamibi dual-tracer SPECT.

Brown adipose tissue is one kind of adipose tissue and regulates body temperature and balance of energy via non-shivering thermogenesis. The authors present a case that strongly suggested the presence of activated brown adipose tissue in the neck, shoulders and axillary space by increased 18F-FDG uptake. 99mTc-sestamibi and 201Tl dual-tracer SPECT study showed increased 99mTc-sestamibi uptake a...

متن کامل

Comparison of 201Tl-chloride SPECT with 99mtc-MIBI SPECT in the depiction of malignant head and neck tumors.

OBJECTIVE Comparison of 201Tl chloride SPECT (TI-SPECT) with 99mTc-MIBI SPECT (MIBI-SPECT) in the depiction of malignant head and neck tumors was prospectively studied. METHODS Forty-one patients with various tumors of the head and neck were included in this prospective study. Histologically, 36 patients had squamous cell carcinomas, 3 undifferentiated carcinomas, 1 transitional cell carcinom...

متن کامل

compensation of cross-contamination in simultaneous 201tl/99mtc myocardial perfusion spect imaging

introduction: it is a common protocol to use 201tl for the rest and 99mtc for the stress cardiac spect imaging. theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. however, a potential limitation is the cross-contamination of scattered photons from 99mtc and collimator x-rays into the 201tl energy window. we used a middle en...

متن کامل

Absolute activity quantitation in simultaneous 123I/99mTc brain SPECT.

UNLABELLED Dual-isotope imaging can allow simultaneous assessment of brain perfusion using a 99mTc-labeled tracer and neurotransmission using an 123I-labeled tracer. However, the images are affected by scatter, cross talk, attenuation, distance-dependent collimator response (DCR), and partial-volume effect. We determined the accuracy and precision of activity quantitation in simulated normal an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Radiological Technology

سال: 1991

ISSN: 0369-4305,1881-4883

DOI: 10.6009/jjrt.kj00003323795